WisDOT Civil 3D 2024 What's new?
Last updated: 2024-12-03
2024-12-04 Version 2024.4
Issue: Plat and TPP Updates
Many updates required to TPP and Plat templates and components.
Summary of Updates:
TPP Title Sheets
-
Extracted the amendment number block (lower right).
- Created a new block (TPP Title Proj-Sheet-Amend No) and stored in ref-plats.dwt and referenced into TPP Title Sheets
- Added Visibility State for the Amendment No Amendment and one that includes an amendment. Default is “No Amendment”
-
Updated the State map in each TPP Sheet template
- Use the same map as in roadway title sheet templates.
-
Update Scale to make it adjustable
-
Update ROW Palette
- Add State map
- Add New TPP Title Proj-Sheet-Amend No
Multileaders
- New multileader style: 070-ARROW-NOTEXT
Dimensions
- Updated ‘070 Plat Conventional’ Dimension style to DMS
Blocks
- Update TPP Project Info block with multiple visibility states for State, Local, and Monumentation plats.
- Updated TPP Detail Sheet border blocks with multiple visibility states for project number, amendment, and sheet number
- New “TPP Detail Notes” block with multiple visibility states for source
- Update Curve Data Abbreviation block to say “CENTRAL/DELTA ANGLE”
- Update TPP Title Notes block to insert “SHOWN” in the portion “IN US SURVEY FEET. VALUES SHOWN ARE GRID COORDINATES”
- Update Schedule of Lands & Interest block
- Added new TPP Revision Date block
- Fixed size of SECCenter block to match other corner symbol corner blocks.
- Added new SEC MC (meander corner block).
- Update standard symbols blocks
- Update Qtr-QtrDesc attribute position in the TLE MAP Title Block.
Survey Figures
- Included key survey figures in the plat template.
Point Styles
- Created new point style “P RW Proposed Right of Way Monumented”, which is a closed/filled circle
- Updated “P RW Proposed Right of Way” point style to be an open circle with mask.
- Set “P RW Proposed Right of Way Monumented” as default
Point Label Styles
- New “IP Text” point label style that includes the text “IP” and the point number
- New “Pnt Number Square” point label
- New “Pnt Number Oval” point label
- Set “Pnt Number Oval” as default
Description Keys
- Add PRW key utilizing “PRW Proposed Right of Way Monumented” point style
- Modify IP key to use “E RW Iron Pipe Pin (No IP text)” point style and “IP Text” point label style
Point Tables
- Add “RW Points NUM STA OFF sort by Point” style
- Update “RW Points YX” style so header reads “Found Monument Table”
Curve Styles
- New “RW Curve” style that includes length, radius, LCB, and LCH
Alignment Styles
- New “PI Station X Y Delta” Point of Intersection label
- New “PI XY ^ D T L R PC PT DB”, “PI XY ^ D T L R PC PT DA”, “PI XY ^ D T L R PC XY PT XY DB”, “PI XY ^ D T L R PC XY PT XY DB” curve labels
Plat Palette
- Move “Plat and TPP Blocks” section of “Lines & Symbols” palette to new palette called “TPP Notes”.
- Create “Annotation” tab with preset text styles for standardization.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-plats.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-point.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-marker-xsection-symbols.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\WisDOTDKS.csv"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP-TITLE30-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP-TITLE34-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TITLE-PLAT-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP34-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP30-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP34-R-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TPP30-R-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\04-TLE-MAP-wdot.dwt"
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\Plats.dwg"
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\WIPaletteImages.dll
- "C:\WisDOT\Stnd\C3D2024\Components\Dimensions\Dimstyles.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Dimensions\Mleaderstyles.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\Plats.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\SectionCorners.dwg"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\AcTpCatalog.atc"
New Files:
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\20-Annotation.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\30-Control Points.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\40-Lines Symbols.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\50-TPP Notes.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\60-Section Corners.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\70-Non-TPP.atc"
Removed Files:
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\20-Control Points.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\30-Lines Symbols.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\40-Section Corners.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\04\Palettes\50-Non-TPP.atc"
Issue: Network Part Refresh
Occasionally a Pipe Network Part may need to re-read the source definition from the Parts List. This may be necessary when changes are made to the Parts Catalog or Parts List.
Solution:
Created a new command DOTRefreshNetworkParts. Command swaps selected parts for the same part in the respective pipe network assigned source parts list. This action re-applies the parameters specified in the parts list, such as the part size properties, rule set, style, and bid items.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon_Light.dll
Issue: Earthwork Detail Report/Slope Stake Report UI enhancements
When there are multiple alignments and sample line groups within a small area. it can be difficult to select the correct start and end sample lines with so many to choose from.
Solution:
When selecting the begin sample line, the last sample line in the group is automatically set to the end sample line and that range of sample lines is highlighted in model space. The “select end sample line” button and “select start sample line” button can be used to change the selected sample line range, and the range will be highlighted.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: Import XReferences from DWG
Users’ request the ability to load a standard set of XReferences.
Solution:
Created new command DOTImportXRefsFromDWG that is found on the Manage panel > XRef Tools menu. User selects a source DWG and all of the dwg XReferences in the source DWG are replicated in the current DWG, including settings for location, name, attach/overlay, layer, and absolute/relative path.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml"
Issue: Publish Collections Manager: Log files
The Publish Collections Manager creates a new log file each time a DSD file is processed. This creates additional clutter in the Publish Collection Directory.
Solution:
No longer keeping previous log files. Log files are now overwritten for each publish event.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll"
Issue: Pipe rule updates
Several pipe rules are not in sync with the FDM.
Solution:
Updated several pipe rules to match the FDM:
- CPRCHE HE-IV: Set max cover to 25 FT.
- SSPRC CLASS II: Set min cover to 2 FT.
- SSPRC CLASS III: Set min cover to 2 FT.
- SSPC: Set min cover to 2 FT.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt"
Issue: Culvert Report: Add note regarding Culvert Pipe Class __ lengths
The bid items for “Culvert Pipe Class __” allows the contractor to provide the pipe material of their choice. Those items in the WisDOT parts lists are reinforced concrete. Since the pipe length for reinforce concrete pipe is shorter than other material types (due to the apron endwall length), a note is needed to inform the contractor that the pipe lengths specified are for reinforced concrete.
Solution:
Add note to culvert pipe table when “Culvert Pipe Class __” items are used.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: AEW Riprap
Need an efficient way to add rip rap symbology to culvert outlet AEWs and quantify.
Solution:
Created a new structure label (Riprap) that matches the plan symbology for riprap. Create a new structure table style for quantifying the riprap (Riprap). These styles utilize a new part parameter to determine the proper riprap size. If the riprap label is not sized correctly in legacy drawings, the DOTRefreshNetworkParts command may be used to update the legacy AEW parts.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-marker-xsection-symbols.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Headwall\USWI_Endwall.xml"
- "C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Headwall\USWI_EndwallReConcrete.xml"
- "C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\AeccSharedPropertyLists.xml"
- "C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\Structures_USWI.apc"
- "C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\Validate\Catalog_Regen_Summary.txt"
Issue: Concrete Barrier linetype updates
A 200 scale version of the RDWY Barrier Edge alignment style is desired. Need an LT/RT offset of the Ecbar linetype with layers and alignment styles.
Solution:
-
Added linetypes
- Ecbarlt
- Ecbarrt
-
Added Layers
- P_RDWY_BarrierConc_LT
- P_RDWY_BarrierConc_RT
-
Added Alignment styles
- RDWY Barrier Edge LT (20 scale)
- RDWY Barrier Edge RT (20 scale)
- RDWY Barrier Edge LT (40 scale)
- RDWY Barrier Edge RT (40 scale)
- RDWY Barrier Edge LT (50 scale)
- RDWY Barrier Edge RT (50 scale)
- RDWY Barrier Edge LT (100 scale)
- RDWY Barrier Edge RT (100 scale)
- RDWY Barrier Edge (200 scale)
- RDWY Barrier Edge LT (200 scale)
- RDWY Barrier Edge RT (200 scale)
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Linetype\wisdot.lin"
- "C:\WisDOT\Stnd\C3D2024\Components\Linetype\Linetypes.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg"
- "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt"
Issue: Additional annotation scales for plat template
Plats occasionally require scales not provided in the current list of annotation scale.
Solution:
Make “1 IN:60 FT”, “1 IN:80 FT”, and “1 IN:120 FT” scales available. Add these scales to plat-start.dwt.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt"
Issue: Update Profile Styles - Model Display Settings
Several profile styles have the 3D chains turned on in model views. They are utilizing the P_Prof_Misc layer and colored white. Update these profile styles so in 3D views, it is more obvious which profile is which.
Solution:
The following profile styles were edited so that the Model display settings match the settings of both section and profile display settings:
- PROF CrossSlope-L
- PROF CrossSlope-R
- PROF Existing
- PROF Proposed
- SD Available Sight Distance
- SD Decision Sight Distance
- SD Stopping Sight Distance
- SE Lane-L
- SE Lane-R
- SE Shoulder-L
- SE Shoulder-R
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt"
Issue: Line labels: line direction relevancy
WisDOT “Slope” line labels are dependent on the direction of the line.
Solution:
Adjust the WisDOT line labels so the line direction is not relevant. Arrow should always point down slope. Text should always be plan readable.
-
Slope Percent
- Slope Ft-Ft
- Slope Ratio
-
Slope Percent (2x Vert Ex)
- Slope Ft-Ft (2x Vert Ex)
- Slope Ratio (2x Vert Ex)
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt"
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt"
Issue: DOTImportDescKeys ignores label style
The DOTImportDescKeys command ignores the label style column in the input CSV file.
Solution:
Command fixed to apply a label style if specified.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: WisDOT Imagery Draw Order
WisDOT Imagery WMS layer does not always load in back.
Solution:
Updated to wait for layer to completely load prior to applying draw order.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: General Notes: Order of sheets table
It can be difficult to insert sheets or modify the order of sheets using the “Order of Sheets” block.
Solution:
Provide an alternative “Order of Sheets Table” block that contains an AutoCAD Table to list the sheet names. Users can use the option that they prefer.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\GenNotes.dwg"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\01\Palettes\20-General Notes.atc"
Issue: Railroad signal blocks
For railroad coordination package, it is required to create a detail of the proposed signal or cantilever mast locations. Need to have the blocks used on SDD 13B01-11A for the railroad signal mast with gate and cantilevered signal mast.
Solution:
Blocks created for Railroad Signal Mast with Gate (RRSIG) and Cantilevered Railroad Signal Mast (RRSIGCNTLVR). Blocks added to 02 Lighting and Signals palette - Traffic Signals plat tab.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\signal.dwg"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\WIPaletteImages.dll"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-7\Palettes\30-Traffic Signal Plan.atc"
Issue: Signal blocks: Insertion points
Several signal blocks do not have the correct insertion point.
Solution:
Adjust signal blocks so the insertion point is centered. Affected blocks include:
- HEAD - OPTICALLY PROGRAMMED - GYR
- MONOTUBE - TYPE 10 BASE
- MAST ARMS
- BASE - PEDESTRIAN
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\signal.dwg"
Issue: “Silt Fence Heavy Duty” Block Edits
Dimensions in “Silt Fence Heavy Duty” block are not scaled correctly.
Solution:
Adjust scale of dimensions.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\cdErosionControl.dwg
Issue: Filter/Rock Bags block
The “Filter Bags” item found in the Erosion Control Legend block needs to be changed to “Rock Bags” to align with the bid item name. The filter bags block needs to be changed to rock bags.
Solution:
Replace ECFILB bag block with ECROCB and edit ECLEG block . Update erosion control palette with block updates.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\Drainage.dwg"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-1\Palettes\cdErosionControl.atc"
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\WIPaletteImages.dll
Issue: WisDOT Civil 3D Plugin version info
Users are not always certain they are on the latest version of the WisDOT Civil 3D Plugin.
Solution:
Added an “About” dialog that includes the build version currently in use with link to what's new page. Also includes Third-Party Trademarks, Software Credits and Attributions.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
Issue: Beam guard detail blocks for Bullnose, Short Radius, Long Span, and Steel Plate Blocks
Need more block(s) for laying out beam guard detailed installations.
Solution:
Blocks have been added for Bullnose, Short Radius, Long Span, and Steel Plate installations.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Parametric\BeamGuard\Palettes\20-Beam Guard Detail.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\WIPaletteImages.dll"
- "C:\WisDOT\Stnd\C3D2024\Components\Blocks\Parametric\param-bg-dtl.dwg"
Issue: "Util-approx" linetypes
Need a way to distinguish approximate utility location (based on system maps/plans) vs surveyed utility locations.
Solution:
Create “util-approx” linetypes and layers which prefix the utility type with “(?)”. For example ----(?)G----. Set to always plot color (Magenta - 255,0,255). Set lineweight to double the parent layer. New layers can be access by using the DOTADDWISLAYERS
command.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Components\Linetype\wisdot.lin"
- "C:\WisDOT\Stnd\C3D2024\Components\Linetype\Linetypes.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg"
- "C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg_LayerList.csv"
Issue: Publish Collections Manager: AcCoreConsole crash
Publishing using Publish Collections Manger or a Publish Collection BAT file results in AcCoreConsole.exe crash because AcCoreConsole.exe does not load the required modules at startup. This typically occurs on devices with Civil 3D and AutoCAD installed side by side.
Solution:
To force load the modules, a '/product C3D' switch was added to the AcCoreConsole startup. Publish collections can be updated by opening/saving them in the Publish Collections Manger.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll"
Issue: Lengths, Areas reports: Select by layer, column sorting (Hotfix 2024.3)
- Select ByLayer option adds entities to the collection repeatedly based on the number in the original selection.
- ‘Layer’ column (Lengths & Areas Reports) and ‘Closed’ column (Areas Report) does not sort with the table data.
Solution:
Remove duplicates from entity collection. Sort all columns in the Excel document.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: Publish Collections Manager: No output (Hotfix 2024.3)
Some Publish Collections run without outputting a pdf of dwf.
Solution:
Publish Collection name has a space in it or DSD path has a space in it. Fix application so it supports spaces in the Publish Collection name and DSD path. Users should update existing Publish Collections by replacing the BatchPublish.dll with the updated one. This can be done manually, or by opening the Publish Collections Manager. Opening the Publish Collections Manger automatically updates the BatchPublish.dll in all Publish Collections.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll"
Issue: Block language
Some blocks have notes that are inconsistent with structures standard details.
Solution
Updated ABUT_FILL, DESIGN_DATA, PILE_DETAILS, WALL_SECTION, CULF_BF, RIPRAP_TOE, and RODENT blocks to match standard details.
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: PGL blocks
The PGL blocks often need to be modified, but the dynamic block is difficult to edit.
Solution
Removed dynamic options and attributes from the PGL and PGL_SUB blocks. Combined the two blocks and removed the PGL_SUB block.
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\08\Palettes\04-Quan.atc
Issue: OLE options
The QUAN and BILL_OF_BARS blocks contain options for inserting OLE tables. It is recommended that drafters use the "Paste Table" tool with Civil 3D tables instead of pasting tables as OLE objects.
Solution
Removed OLE options from QUAN and BILL_OF_BARS blocks.
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: Various block errors
Several errors were reported in blocks that needed to be fixed.
Solution
- ABUT_BACKFILL block: Add slope requirements to wings parallel to abutment detail.
- BAR_PPT block: Fix the 56SS parapet on deck option to display the correct bar details.
- CUL_DATA block: Adjust contractor substitution note.
- CULBF block: Change "Backfill Structure Type A" to "Backfill Structure Type B".
- STRUCT_APPROACH block: Add "T01" and "T03" symbols
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
2024-09-11 Version: 2024.3
Issue: Publish Collections Manager: Unable to Publish DSD files with same name
If a Publish Collection contains multiple DSD files with the same name, only the first one will be processed.
Solution:
The Publish Collections Manager creates temporary SCR files in the %Temp% directory with the same name as the DSD file. When multiple DSD files are named the same, there is a name conflict for the temporary SCR files. The BatchPublish.dll has been revised to create unique SCR names in the %Temp% directory. Users should update existing Publish Collections by replacing the BatchPublish.dll with the updated one. This can be done manually, or by opening the Publish Collections Manager. Opening the Publish Collections Manger automatically updates the BatchPublish.dll in all Publish Collections.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll
Issue: Description keys contain incorrect style assignment
Point description key assignments were updated in February 2024. TEMP* was originally assigned the point style E MARK Temp Shot, but was changed to E MARK Temporary Control Point.
Solution:
Update description keys, CSV, and templates to reflect the correct style assignment.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\WisDOTDKS.csv"
- "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt"
Issue: Earthwork Detail Report cell errors
Some cells in Excel will show #VALUE! error. This is caused by either a reference cell with a value shown as a scientific notation string or a reference cell that is not in number format.
Solution:
Update report so all values are transferred to Excel without scientific notation. Update report to make sure all cells are set to number format.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: WisDOT Imagery: Fond Du Lac County
Imagery not available error due to URL mismatch.
Solution:
Updated WMS URL.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\MapConnections.csv"
Issue: WisDOT Imagery: Kewaunee County
Imagery for Kewaunee County is not loading
Solution:
Imagery Service coordinate system is not se to WISCRS. It is set to State Plane. Adjust WisDOT Imagery add-in settings to match the imagery service coordinate system.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\MapConnections.csv"
Issue: WisDOT Imagery: Milwaukee County
Imagery not available error.
Solution:
Milwaukee County Imagery Service has been taken down and replaced with a WisDOT Milwaukee County Imagery Service.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\MapConnections.csv"
Issue: Plat and TPP Layer Updates
Numerous Changes to Plats and TPP templates, components, blocks, and dwgs.
Solution:
-
Layer Updates
- Changed E_RW_Existing lineweight to 0.02”
- Created new layer E_RW_Text - Use Add Components - Layers command to import into a dwg
Updated Files:
"C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg" "C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg_LayerList.csv" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-point.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-plats.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\WisDOTDKS.csv" "C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt"
Issue: Create Verification Surface: Vol surface style
The “Elevation” style has been replaced with “P Analysis-Elevations”. The Create Verification Surface tool tries to assign the “Elevation” style to the volume surface, but it no longer exists.
Solution:
Update the Create Verification Surface tool to use the “P Analysis-Elevations” surface style if available.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Create Verification Surface command resilience
If the Create Verification Surface tool encounters an error with the given data, it does not complete any operations and it is difficult to determine what portion of the data caused the error.
Solution:
Tool modified to complete whatever operations are possible, given the data’s current integrity. This will result in a partially completed DWG file that will help the user in identifying the erroneous data.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Custom UCS Removed
Custom named user coordinate systems are sometimes removed when the purge non-structures styles tool is used.
Solution
Fixed purge non-structures styles tool so it never removes UCS.
Updated Files
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDot.Bos.Drafting.dll
Issue: Add MSE Section at Abutment
Add a detail showing a section thru an abutment with MSE wall.
Solution
Updated WALL_SECTION block to add section at abutment option.
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: Typo in WALL_SECTION_COPING block
The length of the #4 dowel in the WALL_SECTION_COPING block is incorrect
Solution
Updated WALL_SECTION_COPING to correct the length from 1'-0" to 1'-10"
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
2024-07-17 Version: 2024.2
Issue: Slope Stake Report access violation error
In some situations, the Slope Stake Report results in a fatal error indicating an access violation and Civil 3D crashes.
Solution:
Error would commonly occur when querying a sample line section, but the section had no data at that location. Scenario has been isolated so the error does not occur.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Add Corridor Entity as break line improvements
When the corridor entity is at the edge of a surface, a ‘Point not on Entity’ error is sometimes presented.
Some users are applying this tool to corridor surfaces instead of refinement surfaces.
Solution:
Add a tolerance to account for entities near the edge of a surface. For example, if a link end is at the edge of the surface, use the nearest TIN point instead of the link end point.
Prevent using this tool on corridor surfaces.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: WisDOT Subassemblies help access
Subassembly Help option on the palettes does not connect to the WisDOT subassembly help pages on the KB or to a chm file that has links to the KB.
Solution:
Add a button to each subassemblies/assemblies palette that opens the applicable C3DKB page.
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\10-WisDOT_ROADWAY.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\20-WisDOT_DAYLIGHTS & SLOPES.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\30-WisDOT_GENERAL SUBASSEMBIES.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\40-WisDOT_SUBSURFACE.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\50-WisDOT_SETUP-ASSEMBLIES.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\60-WisDOT_BEAM GUARD-ASSEMBLIES.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\70-WisDOT_INTERSECTION-ASSEMBLIES.atc"
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\80-WisDOT_CROSSOVER-ASSEMBLIES.atc"
Issue: Add WisDOT spell check dictionary
Spell check flags many of WisDOT’s standard abbreviations.
Solution:
Incorporate a WisDOT dictionary that includes all of the standard abbreviations from FDM 15-5 Att 25.1.
Updated Files:
New Files:
- C:\WisDOT\Stnd\C3D2024\Appdata\WisDOT.cus
Issue: WisDOT ‘draw’ tools: Alignment and Polyline support
WisDOT drafting tools found on the WisDOT Design tab → Draw panel only work with arcs and lines. Sometimes users need to draw lines and arcs tangent to alignments and polylines.
Solution:
Support added to draw tangential lines and arcs from existing alignment and polyline sub-entities.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Google Street View access
Google Street View is used often to see ground-level photography along roadway projects. More efficient access to these images is desirable.
Solution:
Provide a button on the WisDOT Image tab to access Google Street View by clicking a point and view direction along on a roadway.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon_Light.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Fix post locations on MGS EAT Curve In parametric block
The posts and blockouts would not move correctly in MGS EAT Curve In when the radius was changed.
Solution:
This behavior was fixed in the block.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\Parametric\param-bg-dtl.dwg
Issue: Add the point code "NoDisplay" to Codes Set Styles
The Codes Set Styles, Color by Link - Point and Link Codes and the Color by Materials - Point and Link Codes are missing the point code “NoDisplay”
Solution:
Add the point code “No Display to both Code Set Styles.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
Issue: Set Storm Structure Plan Label precision to 2 and add a profile slope label for ft/ft
Solution:
Updated each of the Structure Desc labels so the station and offset values are set to 2 decimals. Created a Pipe Plan Profile label named PROF Storm (Ft-Ft) with the slope value formatted as ft/ft.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
Issue: Publish Collections Manager Asynchronous DSD processing
AcCoreConsole crashes unexpectedly when publishing large numbers of sheets (1000s).
Solution:
Publish Collections Manager enhanced to process DSD files asynchronously by creating a new AcCoreConsole session for each DSD file. This all results in a significant performance improvement for Publish Collections with multiple DSD files.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Title Sheet Template. Purge Block Text Styles 2016.14
Old components in the title sheet to clean up.
Solution:
Old components removed.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\01-TITLE-wdot.dwt
Issue: Adjust both the code set Color by* labels to be completely non-annotative
The codes set styles, Color by Link - Point and Link Codes and the Color by Materials - Point and Link Codes point and link labels only have the text set as non-annotative, while the text gaps from objects and line lengths adjust to annotative changes.
Solution:
Adjust the point and label styles used to be completely non-annotative. Text size is completely controlled by the Assembly Label Sizes tool..
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\CodeSets\CodeSets.dwg
Issue: Delete Crdr Lane Marker - Copy Marker Style - ref-align-prof.dwt
Erroneous marker style living in ref-align-prof.dwt.
Solution:
Delete style
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
Issue: Create a surface style for each of the analysis types
There are no available surface styles for the analysis types. End users need to create them from scratch every time they want to use one.
Solution:
Create a surface style of each of the analysis types for existing and proposed. EX Analysis - Directions, EX Analysis - Elevations, EX Analysis - Slopes, EX Analysis - Slope Arrows, P Analysis - Directions, P Analysis - Elevations, P Analysis - Slopes, P Analysis - Slope Arrows
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-surface.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
Issue: Excel report performance
Generating reports in Excel format sometimes result in Excel Interop errors due to MS Office installation/upgrade issues. When generating the report, performance is often slow.
Solution:
Replace Office Interop functions with OpenXML.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
New Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\System.Runtime.CompilerServices.Unsafe.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\System.Memory.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\System.ComponentModel.Annotations.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\Microsoft.IO.RecyclableMemoryStream.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\EPPlus.System.Drawing.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\EPPlus.Interfaces.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\EPPlus.dll"
Issue: Styles Report
Need a report to document all styles contained in a drawing or template
Solution:
DOTReportStyles
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: Missing bearing labels styles
Bearing distance labels were unchecked in the Group-Survey.dwt so they were not feeding into the Survey-start.dwt.
Solution:
Include labels, Bearing, Bearing Distance, and Distance as part of the Group-Survey.dwt labels that gets referenced into the Survey-start.dwt.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt
Issue: BG EAT R Tangent block on palette points to wrong location
BG EAT R Tangent block points to C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-eat.dwg
Solution:
Edit 10-Beam Guard Layout.atc to point to C:\WisDOT\Stnd\C3D2024\Components\Blocks\Parametric\param-bg-eat.dwg for the BG EAT R Tangent block
Updated Files:
- "C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Parametric\BeamGuard\Palettes\10-Beam Guard Layout.atc"
Issue: WisDOT Imagery: Green Lake County
Green Lake County imagery is not loading with WisDOT Imagery
Solution:
Fixed code to look up correct service URL.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: WisDOT Imagery: St Croix County
St Croix County imagery is not loading with WisDOT Imagery
Solution:
Fixed connection URL.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\MapConnections.csv"
Issue: Connect Apron to Pipe
Often culverts get updated and the endwalls take effort to snap and rotate to match.
Solution:
New command created to reconnect AEW structures to pipe at the pipe location. Command is DOTConnectApronToPipe. Is also found on the WisDOT Design tab -> Design Panel -> Pipe Network menu, or the Structure right-click menu.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\HelpResources.csv"
Issue: "Typ Sec Slope Percent" Label corrections
The General > Label Style > Line > Typ Sec Slope Percent needs work. The arrow doesn’t point downhill. The arrow goes through the text. Only works on the segment option.
Solution:
The values and expressions have been updated for the Typ Sec Slope Percent label and the name has been changed to Slope Percent. Additional label styles for slope Ft-Ft and slope ratio have been added as a child to the Slope Percent label. Also, a set of labels for a 2x vertical exaggeration has been added.
Labels:
-
Slope Percent
- Slope Ft-Ft
- Slope Ration
-
Slope Percent (2x Vert Ex)
- Slope Ft-Ft (2x Vert Ex)
- Slope Ratio (2x Vert Ex)
Updated Files:
"C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt" "C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
Issue: Move Pipe End enhancement
If an apron endwall is connected to a pipe, it is disconnected when using the Move Pipe End command on that end of the pipe. If the opposite side of the pipe has an apron end wall, its rotation is no longer correct when using the Move Pipe End command to move the pipe horizonally.
Solution:
Enhance the Move Pipe End command to detect if Inlet/Outlet structures are connected to the pipe. If they are, assure they are connected and rotated correctly after moving the pipe end.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Expressions Report
Need to verify all style expression are valid.
Solution:
Create Expression Report that lists all of the style expression and what they are. DOTReportExpressions is the new command. An Excel document is created in the same directory as the dwg/dwt.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
Issue: Additional CDP Integrity Report checks
Some CDPs have been submitted with empty LandXml files.
Solution:
Add a check to the CDP Integrity Report for LandXml files that do not contain objects.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Update profile line label “Grade” to span profile views
The current profile “Grade” line label does not span profile views.
Solution:
Update the profile “Grade” line label to maintain present function and span profile views.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt
Issue: Create Sample Line export tool
Having the sample lines available in the CDP would allow the contractor to graphically see where earthwork average end areas were calculated. It would also help with performing earthwork finals.
Solution:
Create a tool that collects all the earthwork sample lines for a project and generates a LandXML file.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\HelpResources.csv"
Issue: Process to add point codes to code set style
Best practice is to include unique point codes for various locations in a corridor assembly. Since every project is different unique codes for all possible scenarios cannot be prepackaged.
Solution:
WisDOT provides code set styles with a base/template list of point codes. These codes can be used and appended with a suffix to create unique point codes when building assemblies. A new command, DOTAddPointCodesToCodeSet, is provided to add the unique point codes to the currently assigned code set style or create a new code set style based on the current one. The style assignments from the base code are assigned to the newly add unique codes. Command also found on WiDOT Design tab ->Design panel → Corridor menu.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: Assign Corridor Targets: Multi-Region selection & graphical selection
It can be difficult for users to select the desired corridor region for target assignments because they may not remember the name or station range. Need to apply targets to multiple regions with the same target mapping csv.
Solution:
- Add graphical region selection button in lieu of zoom to region button.
- Add treeview of corridor regions for multiple selections
- Assign targets to multiple selected regions.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll"
Issue: 2025 Pay item file
2025 pay item list has been released and needs to be referenced in C3D.
Solution:
Create pay item file and catalog file for Civil 3D. Reference the new files into the Civil 3D template.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
New Files:
- C:\ProgramData\Autodesk\C3D 2024\enu\Data\Pay Item Data\United States\WisDOT\Categories_2025.xml
- C:\ProgramData\Autodesk\C3D 2024\enu\Data\Pay Item Data\United States\WisDOT\Items_2025.csv
Issue: April 2024 Sign Plate Transmittal
Updates to sign blocks and tool palettes as reflected in the April 2024 Sign Plate transmittal.
Solution:
Signs Added/Revised D7-54C D7-56C MK4-14 R10-11/R10-11D R10-11L/R10-11R RS-Y
Signs Retire (remove) D6-4N D12-2/D12-2A DR1-53 MR5-54 R59-52 RR2-60
Updated Files:
C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsd.dwg C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsm.dwg C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsr.dwg C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\D-Signs.atc C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\M-Signs.atc C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R7-R10-Signs.atc C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R11-R59-Signs.atc C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\WIPaletteImages.dll
Issue: Block Updates
There were several issues found with structures blocks.
Solution
- REVISION block: revised revision triangle to be larger
- SHT2 & SHT2C blocks: revised revision table to match SHT1 blocks
- CULV_JT block: updated to follow changes to the standard details
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
- C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\08-STRUCT.dwt
Issue: Table Horizontal Margin
Horizontal margins on table templates and tables in blocks are too small.
Solution
Doubled the horizontal margin on all structures table styles and blocks with tables. The following blocks were updated:
- BENCH_MARK
- BILL_OF_BARS
- GT_BORING_TABLE
- QUAN
- SHEET_LIST
- TABLE
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
- C:\WisDOT\Stnd\C3D2024\Templates\struct-decimal-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\struct-inch-start.dwt
Issue: Sheet Layout Annotation Scales
Some annotation scales are duplicated when adding a sheet layout. By default, sheet layouts do not display elements that do not have the correct annotation scale.
Solution
- Removed annotation scales from the sheet layout templates.
- Turned on the "Show Annotation Scales" option on sheet layout templates.
Updated Files
- C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\08-STRUCT.dwt
2024-03-20 Version: 2024.1
Issue: Wetland Hatch Pattern
Request to create a wetland hatch pattern that mimics the wetland/marsh block.
Solution:
Added new WETLAND hatch and WETLAND.pat pattern file.
New Files:
- C:\WisDOT\Stnd\C3D2024\Components\Support\wetland.pat
Issue: Slope Stake Report/Superelevation Report worksheet name error message
The Slope Stake Report and Superlevation Report incorrectly produce an Excel Worksheet naming error notification and prevents the report creation.
Solution:
Worksheet naming validation has been corrected.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Set KB link in Ribbon to go to 2024 location
WisDOT C3DKB button on the WisDOT Ribbon tabs links to the 2022 KB page
Solution:
Update Link to go to the 2024 KB page.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\HelpResources.csv
Issue: Reset Subassembly codes
Need a way to reset the point, link, and shape codes to default in subassemblies. This will be useful to take advantage of new code set styles.
Solution:
New command DOTResetSubassemblyCodes provides an option to select subassemblies placed in a drawing and reset user-defined point, link, or shape codes as they are defined in the source palette ATC file. Applies only to WisDOT subasemblies located on the WisDOT subassemblies palettes.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Design surface data extractor in c3d2024 pointing at c3d22 template file location
The design surface data extractor is pointing at C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\x-wisdot.dwt for a template file.
Solution:
Config file updated to point to the 2024 template location.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\AcDesignSurfaceDataExtractor.dll.config
Issue: Survey Codes, Blocks, Point Styles, Description Keys, Survey Prefix Database, Linework Code Set Updates
At the request of the WisDOT Survey data coordinators, several updates have been made to portions of the survey components in the WisDOT Civil 3D Templates.
-
Linework Code Sets
- Continue: blank
- Close changed to “C”
-
Blocks
- New blocks GSM, TIMP
-
Point Styles
-
New: E Mark Check Point, P MARK Geodetic Survey Monument, P RW PLSS Corner Monument, E MAP Validation Point
-
Update:
- E MAP Total Image Point: Use TIMP block
- E MARK Resection Control Point : Use “+” instead of SEC block
- Rename “E MARK Temp Shot” to “E MARK Temp Control Point”
- P MARK Temporary Benchmark: Use “+” instead of BM block
- E RW Iron Pipe Pin (With IP text): Change block from “IP” to “IPF”
-
-
Description Keys
- New: CK, GSM, PLSS, VP, TIMP
- Rename: PRW to NRW
- Delete: AZMK
-
Survey Prefix Database
- Rename: PRW to NRW
- Delete: SEC, QTR, SIXL, PROP, RW
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-marker-xsection-symbols.dwt
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\MarkerSymbols\MarkerSymbols.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\MarkerSymbols\XSectionSymbols.dwg
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\WisDOTDKS.csv
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-point.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\survey-start.dwt
- C:\ProgramData\Autodesk\C3D 2024\enu\Survey\WisDOT Topography.fdb_xdef
- C:\ProgramData\Autodesk\C3D 2024\enu\Survey\WisDOT.f2f_xdef
Issue: Add standard typical section layers to Typical Section Template
The typical section template and Palette is missing some of the standard Typical Section Layers.
Solution:
Add the standard typical section layers to the template and Palette. These layers are also added automatically when creating typical section drawing using the DOTStartTypicalSectionDWG
command from the typical section sheet palette.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\02-TS-SPSHT-wdot.dwt
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-2\Palettes\10-Startup Main.atc
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
Issue: Beam Guard - Thrie Beam Transition assemblies missing
Buttons for the WisDOT ‘Beam Guard - Thrie Beam Transition’ assemblies are missing from the Beam Guard palette.
Solution:
Add buttons for “Beam Guard - Thrie Beam Transition” and “Beam Guard - Rehab - Thrie Beam Transition” assemblies to the Beam Guard palette.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\60-WisDOT_BEAM GUARD-ASSEMBLIES.atc
Issue: Beam Guard Assemblies: DLPC Offset to measure clear zone from
The WisDOT beam guard assemblies do not have the left side Daylight Profile Controlled parameter ‘Offset to measure clear zone from’ parameter set to a negative value.
Solution:
Set the value to -12 on all left side DLPC instances in the WisDOT ‘Beam Guard’ and ‘Beam Guard - Rehab’ assemblies.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Rehab-NoLane-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Rehab-TBT-NoLane-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-TBT-Profile Slope Control.dwg
Issue: Improvements to match line label styles
WisDOT does not have a match line label style that is usable at the intersection of the alignment and match line. Also, need more options for match line labeling.
Solution:
Added new match line label styles for both left and right:
Station-Center:Intended for placing a match line label at or near the center of the match line which requires match line label location of "Alignment Intersection" or "Middle."
Station (No Plot):DOES NOT PLOT - Intended for placing a match line label at the start/end of the match line on the right/left side of the match line, which requires match line label location of “Start” or "End."
Set default match line label [Left and Right] in both design-start.dwt and plat-start.dwt to Station (No Plot).
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\plat-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
Issue: DaylightProfileControlled/CutFillProfileControlled Regression
DaylightProfileControlled pkt does not contain Clear Zone Width from profile target parameter and CutFillProfileControlled pkt doe not contain Recoverable distance from profile target parameter.
Solution:
Update subassembly pkt files with the missing target parameters.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\Subassemblies\DaylightProfileControlled.pkt
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\Subassemblies\CutFillProfileControlled.pkt
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT Rural Full Section.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT Rural Full Section-Conditional.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT Rural Driveway.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Rehab-NoLane-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-Rehab-TBT-NoLane-Profile Slope Control.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\WisDOT BG-TBT-Profile Slope Control.dwg
Issue: Manhole/Inlet cover part families
Multiple requests for larger structures combined with various inlet covers.
Solution:
Add new cylinder Manhole/inlet cover part families so inlet covers can be paired with larger cylinder structures.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\AeccSharedPropertyLists.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\Structures_USWI.apc
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\Validate\Catalog_Regen_Summary.txt
New Files:
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type A Covers\USWI_Cylinder_Manholes 3-8_A.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type A Covers\USWI_Cylinder_Manholes 3-8_A.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type A Covers\USWI_Cylinder_Manholes 3-8_A.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type B Covers\USWI_Cylinder_Manholes 3-8_B.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type B Covers\USWI_Cylinder_Manholes 3-8_B.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type B Covers\USWI_Cylinder_Manholes 3-8_B.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type F Covers\USWI_Cylinder_Manholes 3-8_F.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type F Covers\USWI_Cylinder_Manholes 3-8_F.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type F Covers\USWI_Cylinder_Manholes 3-8_F.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type H Covers\USWI_Cylinder_Manholes 3-8_H.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type H Covers\USWI_Cylinder_Manholes 3-8_H.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type H Covers\USWI_Cylinder_Manholes 3-8_H.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type S Covers\USWI_Cylinder_Manholes 3-8_S.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type S Covers\USWI_Cylinder_Manholes 3-8_S.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type S Covers\USWI_Cylinder_Manholes 3-8_S.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type T Covers\USWI_Cylinder_Manholes 3-8_T.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type T Covers\USWI_Cylinder_Manholes 3-8_T.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type T Covers\USWI_Cylinder_Manholes 3-8_T.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type V Covers\USWI_Cylinder_Manholes 3-8_V.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type V Covers\USWI_Cylinder_Manholes 3-8_V.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type V Covers\USWI_Cylinder_Manholes 3-8_V.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type WM Covers\USWI_Cylinder_Manholes 3-8_WM.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type WM Covers\USWI_Cylinder_Manholes 3-8_WM.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type WM Covers\USWI_Cylinder_Manholes 3-8_WM.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type Z Covers\USWI_Cylinder_Manholes 3-8_Z.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type Z Covers\USWI_Cylinder_Manholes 3-8_Z.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type Z Covers\USWI_Cylinder_Manholes 3-8_Z.dwg
Issue: Add Concrete Collar Part
Users request a concrete collar part be added to the parts catalog, Storm Sewer part list and Culverts parts list so they can be documented for quantity take off.
Solution:
Concrete collar part added to catalog, Storm Sewer Parts list, and Culverts Parts list. Collar height and width will automatically size for circular pipe. For elliptical and arch pipes, collar automatically sizes for height. Use the structure width parameter to add additional width as needed.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\AeccSharedPropertyLists.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\Structures_USWI.apc
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\design-start.dwt
New Files:
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Manholes\USWI_Collars.bmp
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Manholes\USWI_Collars.dwg
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Manholes\USWI_Collars.xml
Issue: New structure types for parts catalog
Need to incorporate changes from most recent FDM update Transmittal #431
- 611.0655 Inlet Covers Type V-B
- 611.0656 Inlet Covers Type VV-B
- 611.3260 Inlets 2x3.5-FT
Solution:
- Add pay item files for 2024 spec year.
- Add CATCH BASINS 3-V-B
- Add CATCH BASINS 4-V-B
- Add CATCH BASINS 5-V-B
- Add CATCH BASINS 6-V-B
- Add CATCH BASINS 8-V-B (Non-Standard)
- Add CATCH BASINS 5-VV-B
- Add CATCH BASINS 6-VV-B
- Add CATCH BASINS 8-VV-B (Non-Standard)
- Add MANHOLES 5-VV-B
- Add MANHOLES 6-VV-B
- Add MANHOLES 7-VV-B
- Add MANHOLES 8-VV-B
- Add MANHOLES 9-VV-B
- Add MANHOLES 10-VV-B
- Add MANHOLES 12-VV-B (Non-Standard)
- Add INLETS 3-V-B
- Add INLETS 4-V-B
- Add INLETS 2x2.5-V-B
- Add INLETS 2x3.5-VV-B
- Add INLETS 2x2-S
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type V Covers*
New Files:
- C:\ProgramData\Autodesk\C3D 2024\enu\Data\Pay Item Data\United States\WisDOT\Items_2024.csv
- C:\ProgramData\Autodesk\C3D 2024\enu\Data\Pay Item Data\United States\WisDOT\Categories_2024.xml
- C:\WisDOT\Stnd\C3D2024\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type VV Covers*
Issue: Rename and configure Dim styles
Current Dimstyle names are based on specific uses instead of denoting the generic dimension style.
Solution:
Add generic dimension info to the tooltip description on the Dimension and Sheet palettes. Removed PLAN from the dimension style names and renamed the 0#0-PLAN JOINTS NO DIM LINES to 0#0-TXT ONLY.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Dimensions\Dimstyles.dwg
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Standards\Wis-Dims\Palettes\10-Dimension Styles.atc
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-1\Palettes\10-Startup Main.atc
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-2\Palettes\10-Startup Main.atc
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-3\Palettes\20-Intersection Details.atc
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-4\Palettes\10-Startup Main.atc
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Sheets\02-6\Palettes\10-Startup Main.atc
Issue: C3D 2024 does not automatically update View Frame template source
When sheet drawings are opened in C3D 2024 that were previously in an earlier version of C3D (2020 & 2022), the view frame template source is not updated to the C3D 2024 version. If the template from the previous version of C3D is not available, and error occurs.
Solution:
Rename sheet template directory to: C:\WisDOT\Stnd\C3D2024\Templates\Plan Production
Changed Plan(s) Only default template path to C:\WisDOT\Stnd\C3D2024\Templates\Plan Production\05-PN-DUAL-PLN-wdot.dwt. Changed Profiles(s) Only default template path toC:\WisDOT\Stnd\C3D2024\Templates\Plan Production\05-PN-DUAL-PROF-wdot.dwt.
Civil 3D 2024 will then find and automatically migrate all of the view frame template source paths as expected.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Res\2024wisdot.arg
New Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Plan Production*.dwt
Removed Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Sheets*.dwt
Issue: PS Girder Plan
Incorrect pier bearing pad width on PS_GIRD_PLAN block.
Solution
Updated PS_GIRD_PLAN to decrease default pier bearing pad widths by 4".
Updated Files
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: Inconsistent Block Scale
Some blocks are set to a default scale that is inconsistent to similar blocks on other palettes. Other blocks are not scaled consistently and have no notice to drafters.
Solution
- Set all blocks to insert at a default scale of 1.0
- Removed auto-explode on bar bend diagrams to allow easier scaling
- Added attributes and visibility states to all BAR_BEND blocks to allow common details to be edited without exploding the block. This allows the blocks to be used with different scales.
- Fixed the scale on BATTER_ARROW, CULV_HEADER, HAUNCH, SLAB_SECTION, SLAB_SECTION_NOTCH, STRUCT_APPROACH, and WALL_SECTION_SLAB
Updated Files
- C:\WisDOT\Stnd\C3D2024\AppData\ToolPalette\Sheets\08\Palettes\03-General.atc
- C:\WisDOT\Stnd\C3D2024\AppData\ToolPalette\Sheets\08\Palettes\06-Rebar.atc
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: Paste Table Tool Error
The Paste Table tool will crash if you paste data too large for the table in a cell other than the top left cell.
Solution
Updated the Paste Table tool to correct the error.
Updated Files
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDot.Bos.Acad.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDot.Bos.Drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDot.Bos.Geometry.dll
2024-01-31 Version: 2024.0
Issue: Templates Audit
Over years of updates, the templates contained extra styles in locations, incorrect default styles, and other problems
Solution:
In-depth analysis of templates, adjustments, and updates.
- ref-dwg-settings.dwt and ref-ex-dwg-settings.dwt have been removed as the only thing they were providing was Drawing Settings > Default Layers. The start templates were updated to include the desired default layers
- All command settings were reviewed for relevancy to the particular template discipline.
- All group templates > reference template defaults were reviewed for that template discipline.
- Delete all “XS” and “E XS” Link Styles - From the Caice Days
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-parcel.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-pipe.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-point.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-section.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-corridor.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-surface.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-xxx.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-property-sets.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-plats.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-marker-xsection-symbols.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-masshaul.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\plat-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\survey-start.dwt
-
C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\x-wisdot.dwt
Removed Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-dwg-settings.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-ex-dwg-settings.dwt
Issue: Update reference template paths
Need a way to update the reference template paths when changing Civil 3D versions.
Solution:
There is no way to access the reference templates paths using the Civil 3D API. However, mouse actions and keystrokes can be simulated using the Window UI Automation API. A reference template find/replace/remove function has been added to the Sync Project Files tool to update reference template paths for the given list of drawings.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Settings migration tool
Users need to spend time resetting their preferences when moving to a new version of Civil 3D.
Solution:
Develop DOTMigrateUserSettings command to migrate Civil 3D 2022 user settings to Civil 3D 2024, including:
- Command line registry
- Drawing window registry
- Toolbars registry
- My places registry
- Select user system variables (WisDOT profiles only)
- Contents of C:\WisDOT\Stnd\users\Myc3d2022
- Palettes, Action macro recordings, assembly files, block files, Publish Collections
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
Issue: WisDOT Imagery
Need a way to give users a simple mechanism to access the latest aerial imagery available.
Solution:
New contextual ribbon tab “WisDOT Imagery” is visible when a coordinate system is assigned to the dwg. The tab contains options to display topographic or county-specific aerial imagery, depending on the assigned coordinate system. Options to stylize the imagery with brightness, contrast, opacity, and color controls are provided. Imagery can be captured to a reference local image file of a specific area.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon_Light.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\Magick.Native-Q8-x64.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\Magick.NET.Core.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\Magick.NET-Q8-x64.dll
New Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\MapConnections.csv
Issue: Remove Orphaned Image Files
With the introduction of “WisDOT Imagery”, it is more likely that projects could accumulate many unreferenced image files. A tool is needed to scan project directories to find any image files that are not being referenced into project dwg file.
Solution:
New command DOTRemoveOrphanedImages prompts user to select a project directory to scan. The tool looks for all image files (PNG, JPEG, TIFF, TIF, SID) in the selected directory and subdirectories. Then it opens each dwg database in the same directories and checks if any of the found images have been referenced. It first checks if images were referenced as an “XRef” (MAPIINSERT). Then it determines if there are any FDO Raster connections. Drawings with FDO Raster connections are opened at the end to determine if those connections are to any of the found image files.
Once a list of orphaned images is developed, the user is presented with a list of the images. The user can select which images to delete from the project directory.
The command is located in the Manage panel - Project menu.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\HelpResources.csv
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Model Display Options
Users have different color preferences when viewing certain entities in Model space. However, these entities need to plot according to WisDOT standards. Need a way to override the color display of the certain entities (Profile View grid, Section View grid, Surface contours) in Model space while keeping the colors set to the WisDOT standards for paper space (plotting). Users should not be modifying the CTB according to their personal preferences because the CTB controls plotting and the CTB needs to be the same on all devices.
Solution:
The Model Display Options tool has been added to the Manage panel on each WisDOT ribbon tab. Users can use this to set their Model Space color preferences for Profile View grids, Section View Grids, and Surface Contours. These preferences can be set globally across of these object types, or users can set use the provided layer filter option to specify which entities should be affected.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\PackageContents.xml
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Add Apply Layer State tool to WisDOT ribbon
The Apply Layer States tool is accessible via the Layer Colors Manager and command line. However, it would be more convenient if this tool was available on the WisDOT ribbon tabs.
Solution:
Created a command button and added it to the WisDOT Ribbon tabs - Manage panel - Layer Tools menu.
Layers - Apply Layer State (wi.gov)
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Fix post location and rotation on curved thrie beam transition blocks
The location and rotation of posts and blockouts in MGS Thrie Beam Transition Curve In and MGS Thrie Beam Transition Curve Out were incorrect. They have been fixed.
Solution:
Fix the location and rotation of posts and blockouts.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\Parametric\param-bg-dtl.dwg
Issue: Point Station Offset to UDP not updating points located at curve ends
C3D API defect related to tolerances. In some cases, if an alignment curve type is “fixed” there may be an extremely small tangency violation at the curve end that is not reported in the alignment geometry table. However, the violation is still detectable by the API and the station/offset location is reported as “out of range”. The tool therefore does not compute the sta/os at that location.
Solution:
Compute the station/offset whenever possible regardless an “out of range” return from the API. If truly out of range (beyond alignment ends), the UDP for alignment description will indicate “OutOfRange”.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Modify length, area, and 3d area reports to be able to send multiple selections to the same xlsx file
Users requested that these tools be modified to allow for multiple selection sets to be sent to the same xlsx file. They can go to different sheets, but being able to work within the same file would be valuable.
Solution:
Updated to include user input for Worksheet name. Output will append to existing file with the new worksheet. If the worksheet exists, there is a prompt for overwrite.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: CGBasic MCO curb height
The SDD for Milwaukee County curb and gutter shows a 6” curb height. CGBasic has the curb height at 7”.
Solution:
Set curb height to 6” for Milwaukee County curb and gutter in CGBasic.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Assemblies\Subassemblies\CGBasic.pkt
- C:\WisDOT\Stnd\C3D2024\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\10-WisDOT_ROADWAY.atc
Issue: Add INSTALL (no text) visibility state to some sign blocks
Solution:
Add new visibility state INSTALL (no text) whenever the blocks are updated.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsd.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signse.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsg.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsi.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsj.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsm.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsr.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signss.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\signsw.dwg
Issue: Rename alignment style _No Markers to ALI Proposed (No Markers)
_No Markers is often used by designers. Sometimes more often than ALI Proposed. But the name of _No Markers has made discovery of this style difficult. Renaming it to ALI Proposed (No Markers) will make it more discoverable and bring it in line with the naming of the existing styles.
Solution:
Updated _NoMarkers Alignment Style to ALI Proposed (No Markers).
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: Create Alignment Style for Sidewalk Joints
Only one alignment style for sidewalks (RDWY Sidewalk). Need a style for curb ramp design and joints in curb ramps.
Solution:
Add Alignment Style RDWY Sidewalk Joints
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: Set default profile label set to _No Display
It is easier to add a profile label set after creation rather than deselecting profiles.
Solution:
Set default profile label set to _No Display
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: Set default cross section crossing label to <none>
This is a step in published training that can be removed if the default is changed
Solution:
Set default cross section crossing label to <none>.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: Alignment styles: remove markers for through points and station reference points
Through points and station reference points should not be displayed in alignment styles.
Solution:
These markers will be turned off.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\survey-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\plat-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
Issue: Update Create Corridor Surfaces tool to account for custom point codes
It is advantageous to create custom point codes to have better success with corridor feature line continuity. The accompanying csv file does not include wildcards for the feature line codes.
Solution:
Update the tool to read feature line codes with wildcards to facilitate automation while using custom point codes. For example, a feature line code of ETW* would read ETW_L_In and ETW_L_Out.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\CreateCrdrSurfs.csv
Issue: Add Corridor Entity as Breakline: Point outside surface error
This error can occur when multiple surfaces are part of the target surface definitions. The tool iterates through each surface to find the appropriate surface to tied the feature line end point too. If it encounters a surface in the definition that is not in the area of the feature line, the error occurs.
Solution:
Updated the code to determine if a contributing surface is in the area of the breakline.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Assign Corridor Targets - Exception when multiple possible surface targets
An unhandled exception occurs when multiple surfaces existing in a drawing that meet the Assign Corridor Targets csv search criteria.
Solution:
Notify the user when this scenario occurs so they can refine their csv search criteria. Surface targeting is skipped in this scenario, but other targeting will still occur.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Assign Corridor Targets- Case Insensitive
Assign corridor targets will not find objects if the case does not exactly match.
Solution:
Set the match criteria to case-insensitive.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Add new Code Set Styles
Add new code set styles that display additional subassembly data to help designers more easily see geometric design information.
Solution:
The following code set styles have been added under General > Multipurpose > Code Set Styles:
- Color by Link - Point and Link Codes
- Each corridor link has a unique color based on the subassembly link codes and the Material Area Fill Style in the code set style. The subassembly shapes are also assigned unique colors for display in section views.
- Color by Link - Point and Link Codes - Rendered
- Same as "Color by Link - Point and Link Codes". Render materials are included in this code set style for 3D viewing.
- Color by Top Materials - Point and Link Codes
- The top of roadway materials are based on the Link - Material Area Fill Styles in the code set style. Examples materials: concrete pavement, asphalt pavement, base aggregate, grass. This code set is not to be used to determine material quantities.
- Color by Top Materials - Point and Link Codes - Rendered
Same as "Color by Top Materials - Point and Link Codes". Render materials are included in this code set style for 3D viewing.
Styles
Additional styles have been created in order to build the code set styles:
- General > Multipurpose > Link Styles
- General > Multipurpose > Shape Styles
- General > Multipurpose > Label Styles > Link
-
General > Multipurpose > Label Styles > Marker
Layers:
- P_CRDR_VisualizationLink
- P_CRDR_VisualizationShape
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg
- C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg_LayerList.csv
Issue: Import Code Sets with Render Materials
Code set styles “Color by Link - Point and Link Codes - Rendered” and “Color by Top Materials - Point and Link Codes - Rendered” need AutoCAD render materials to view corridor link material areas in 3D. The rendered code sets and materials are not included in the design-start template.
Solution:
Added new command DOTImportCodeSetStyles and button located at WisDOT Design tab > Design panel > Corridor menu > Import Code Set Styles. Command imports all codes sets and associated render materials from “C:\WisDOT\Stnd\C3D2024\Components\Assemblies\CodeSets\CodeSets.dwg".
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\xaml\wisdot-ui.xaml
New Files:
- “C:\WisDOT\Stnd\C3D2024\Components\Assemblies\CodeSets\CodeSets.dwg
Issue: Rename CRDR Proposed code set styles
With the addition of more code set styles, a more descriptive naming convention is needed to convey what each code set displays.
Solution:
The following styles were renamed:
General > Multipurpose > Code Set Styles:
- Crdr Proposed > General
- Crdr Proposed - Point and Link Codes > General - Point and Link Codes
-
Crdr Proposed - Point Codes > General - Point Codes
General > Multipurpose Styles > Feature Line Style:
-
Crdr Proposed > General
General > Multipurpose Styles > Link Styles:
- CRDR Proposed > General
- CRDR Proposed - Top > General - Top
- Datum > General - Datum
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: Control General Corridor Link Color by Layer
Update P_Crdr_Link Layer and General Link style so the corridor link color for the General code sets can be updated using layer settings. Allows for a less intrusive corridor link look when designing and working with corridors while using the General code sets.
Solution:
-
General (old CRDR Proposed) Link Style has been updated to display color “ByLayer”
- Used to be Color 30.
- Uses the layer P_Crdr_Link
-
Modified Layer P_Crdr_Link lineweight to 0.005 (Was 0.016)
-
Add Link Style “XS” hardcoded to color 30 and lineweight of 0.016 for use in XS Surface Check Code Set Style.
-
Updated layers.dwg layer settings and layer states
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg_LayerList.csv
- C:\WisDOT\Stnd\C3D2024\Components\Layers\Layers.dwg
Issue: Assembly and Section Editor Default Code Set
New code sets available are very good for assembly layout and corridor section editor display
Solution:
Update the default code set or both Assembly settings and Section Editor view options to be Color by Link - Point and Link Codes
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\design-start.dwt
Issue: DOTRotateAnnoToViewport not rotating correctly
The tool does not rotate entities properly in certain situations. Also, the entities are not rotated for each assigned Annotation Scale.
Solution:
Entity positions for non-current Annotation scales are removed. Adapted tool to rotate correctly in all situations.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: SSMDetectMode System Variable
Default is set to 1 which loads the Sheet Set Manager for Web by default when available.
Solution:
Set variable to 0 in WisDOT profile arg files. Any time the WisDOT profile is created or reset, the variable will be set to 0. However, users can change this at any time after. For internal WisDOT devices, the user preference for this setting will be saved and can be reloaded using the Restore User Setting command.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Res\2024wisdot.arg
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Res\2024wisdotBOS.arg
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Initializer.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Publish Collections Manager - Only processing first 2 DSD files
Only the first two DSD files in a Publish Collection are being processed.
Solution:
Publish from Application context.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-US\BatchPublish.dll
Issue: Update WisDOT Design > Contractor Data to Data for Construction
Contractor Data Packet has been renamed to Construction Data Packet to better reflect the wide-spread usage of this data throughout the construction stage of a project.
Solution:
Renamed button to “Data for Construction” and updated any relevant tooltips.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Menu\WiRibbon.cuix
Issue: Design Surface Data Extractor cannot complete extraction when invalid link code is encountered
If a link code is encountered in a corridor surface definition, but that link code does not exist in the corridor, the Design Surface Data Extractor encounters an error and aborts the extraction process.
Solution:
The error derives from the DSDE attempting to compute stations and offsets of links that do not exist. The purpose of obtaining the stations and offsets was to compute the end points of the links so line objects could be built in the resulting file. The station value was also included in the link XData. The code has been modified to extract the link endpoints' XYZ values directly. The station value has been removed from the XData.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\AcDesignSurfaceDataExtractor.dll
Issue: Design Surface Data Extractor (DSDE) Defects
In certain situations the DSDE will miss break lines that follow and interior pasted boundary (such as Daylight_Sub). Also, in certain situations the DSDE will break break lines into 2 segments cause an erroneous “LINE_NO_MATCH” flag.
Solution:
Prevent the DSDE from flagging break lines for later trimming if one end is on the design surface boundary and the other end is inside the boundary. Now it will only trim break line that span the outer boundary.
Moved the processing of identifying “LINE_NO_MATCH” break lines ahead of the process of deleting break lines that have been overridden by surface pastes. This was done to further filter the break lines flagged for deletion to only those that do not match the surface. It is assumed that if a line matches the design surface, it is valid and should not be deleted.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\AcDesignSurfaceDataExtractor.dll
Issue: CDP Integrity Report enhancements
- Report does not flag DWG files with images attached.
- Report does not flag DWG files with PDFs attached.
- Report does not flag DWG files with DWFs attached.
- Report does not flag DWG files with DGNs attached.
- Report does not flag DWG files that are not version 2010.
Solution:
Report enhanced to flag DWG files that have images, DWFs, DGNs, and PDFs attached or are not version 2010.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\WisDOT.Extensions.dll
Issue: Structures - Updated Blocks
- Update names in DESIGN_CONTACTS block
- BAR_STIRRUP2 bar length does not change with bar section
- Incorrect layers in BAR_STIRRUP, BAR_U, BAR_L, BAR_HOOKED, BAR_LAP
- Incorrect scales in LIGHT, PPT_TRANSITION, NARR, CULBFNOTE, CULNOTE, BENCH_MARK, GT_BORING_TABLE, GT_GRID, TANOFF, TOD, DEFLECTION
Solution:
Updated the blocks to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
Issue: Structures – New Blocks
- WALL_SECTION – Add options for wall under anchor slab and wall under approach slab
- WALL_SECTION_COPING – Detail thru typical MSE wall coping
- WALL_SECTION_SLAB – Detail thru typical MSE wall anchor slab
Solution:
Added new blocks requested
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\Blocks\structures.dwg
- C:\WisDOT\Stnd\C3D2024\AppData\ToolPalette\Sheets\08\Palettes\11-Wall.atc
- C:\WisDOT\Stnd\C3D2024\AppData\ToolPalette\Sheets\08\Palettes\12-Misc.atc
Issue: Structures – Check Drawing Type
The Check Drawing Type tool in the Structures tool Palette does not tell you the drawing type if nonstandard styles or annotation scales are in the drawing.
Solution:
Updated the tool to always let you know which structures template was used to start the tool. It will then let you know if there are any nonstandard styles or annotation scales.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\wisdot.bos.acad.dll
Issue: Structures – Purge Non-Structures Styles
The Purge Non-Structures Styles tool does not remove materials, detail views, and other non-block elements.
Solution:
Updated the tool to purge all unused styles and elements except standard structures styles and layers.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\wisdot.bos.acad.dll
Issue: Structures – New Profile settings
· FILETABPREVIEW = 0
· FILETABTHUMBHOVER = 0
· OSNAPZ = 1
· EDGEMODE = 1
Solution:
Updated the WisDOT Structures profile to apply these settings
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\en-us\BosData.txt
Issue: Add Sheet Set Template
Structures templates do not currently work in a sheet set
Solution:
Created a sheet set template. Updated sheet layout templates to work with the sheet set. Added list of drawings table style to drawing template.
Updated Files:
- C:\WisDOT\Stnd\C3D2024\Components\SheetSets\StructuresSheetData.dst
- C:\WisDOT\Stnd\C3D2024\Templates\Sheets\08-STRUCT.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\struct-decimal-start.dwt
- C:\WisDOT\Stnd\C3D2024\Templates\Begin-dwg\struct-inch-start.dwt
Issue: Paste Table Tool
The paste table tool will always paste data into the upper left cell.
Solution:
Add input for row/column to paste data to.
Updated Files:
• C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.3.bundle\Content\wisdot .bos.drafting.dll