WisDOT Civil 3D 2022 "What's new?"
Last updated: 2023-09-14
2023-09-08
Issue: Add single corridor link to surface definition
Need an efficient way to add a breakline to a surface that mirrors a corridor link.
Solution:
New command DOTAddCorridorEntityAsBreakline. Command prompts for the surface to edit and then the corridor subentity to add to the surface definition as a breakline. A corridor link or feature line segment may be selected. Corridor entities can only be added to the surface definition if the end points are on the surface. The selected entity is converted to a siteless feature line and the feature line is added as a breakline. The feature line is named "BreaklineFromCrdrEntity#". If the entity end points are on a surface that was pasted into the surface being edited, the feature line elevations are set relative to that surface. Otherwise, the feature line elevations are static.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll"
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml"
Issue: Assign Xrefs to layers unhandled exception
Command sometime results in an unhandled exception “eKeyNotFound”.
Solution:
The error is caused by Xreferences that have Xreferences set to “Attach” instead of “Overlay”. Tool has been updated to ignore nested Xreferences.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Purge Unused References locked layer unhandled exception
There is an unhandled exception when attempting to purge a reference that is on a locked layer.
Solution:
Mark entities in the UI that cannot be purged because they are on a locked layer.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: CDP Integrity Report: false extraneous file flag, C3D file detection missing
If a dwg or xml file extension is upper case, the CDP integrity report will give a false “Extraneous file” flag.
Some Civil 3D entities are not being detected.
Solution:
Extraneous file check corrected to account for upper and lowercase file extensions.
Expanded Civil 3D object detection.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Add Multileader update block dependency
Add Multileaders does not update block dependencies.
Solution:
Tool updated to update any block definition dependencies.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Point Station/offset to UDP unhandled exception
An unhandled exception error occurs when running this tool without the “USWI-Alignments” UDP classification present in the dwg.
Solution:
In certain situations, the tool is unable to create the classification at runtime without locking the document. Added a document lock to assure the classification creation at runtime.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Create Data Links & Tables relative path
The relative path option is not functioning properly under all scenarios.
Solution:
Fixed relative path logic to account for additional scenarios.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Simplify Layer State Names on palette
Layer state names on the Layer State palette are wordy and inconsistent.
Solution:
Update Layer state names on the Layer State palette.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Layers\Palettes\10-LayerStates.atc
Issue: Formalize 3D Surface Area Note Label
Existing 3D surface label existed in ref-property sets and was too cumbersome for everyday users to get to work with the property set.
Solution:
Formalized the 3D surface area note label in ref-general and make it available in design and survey.
Updated Files:
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-property-sets.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt"
- "C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt"
Issue: Existing Manhole (Production) Structure Style is using the wrong block
The Existing Manhole (Production) Structure Style is using the MHpn block which has the insertion point between the manhole symbol and the text which puts the manhole offset from the actual location.
Solution:
Update the MHpn Block so the insertion point is in the center of the circle.
Updated Files:
-
"C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-point.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-marker-xsection-symbols.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkerSymbols\MarkerSymbols.dwg"
Issue: Alignment Label Sets with [DESC] show the "Circle" component
Label Sets contain Geometry point labels. The Labels that contain {DESC} contain the Circle Component.
Solution:
[DESC] Geometry Point Label Styles updated to remove the Circle Component.
Updated Files:
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt"
-
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt"
Issue: Add Default codes to Subassemblies and Subassembly Palettes
Many subassembly links do not have unique codes. This makes it difficult to develop detailed code set styles to aid in design development and create visualization code set styles.
Solution:
Add unique link codes to subassemblies.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\10-WisDOT_ROADWAY.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\20-WisDOT_DAYLIGHTS & SLOPES.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\30-WisDOT_GENERAL SUBASSEMBIES.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.atc & 5f34377da7dd41908417dd238e466f48.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic2\f020c97d2ec24d5688426b0fec79ae41.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\LinkProfileControlled\aab45c08008441b688d9fe9bba30ca8d.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\LnExtendBase\f7be9312e1d54d3798bf626fa8196c69.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\MedianDaylight\28faf28e3af4420295a45d27cd731988.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\MedianDitchorBerm\730b3f827182446d9419cecea8be9349.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\ShldGeneric\0855084cdefa4cb1a9ba3ba515c61ab8.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\SidewalkWithBase\e07db9e33c4941339b5b5db7fdd9d59c.atc
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Rehab-NoLane-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Rehab-TBT-NoLane-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-TBT-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Curb Return Fillet.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Rural Full Section.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Rural Full Section-Conditional.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Shoulder Return Fillet.dwg
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: Surface from PNT/FLT crashes Civil 3D
For certain data sets, Civil 3D will become unresponsive when building a surface from PNT/FLT files.
Solution:
Add show boundaries as a single collection instead of individually.
Updated Files:
-
"C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll"
Issue: Structures - Updated Blocks
- Fix typo in SHT1C sheet border block
- Remove “Scale” field on sheet borders
- Update names in DESIGN_CONTACTS block and fix issue with dropdown assigning to incorrect fields
- Update bearing pad width in PS_GIRD_PLAN block
- Update testing requirements in BEAMGUARD_ASSEMBLY block
- Make grips visible on all visibility states in BAR_SPACED block
- Update TABLE block to work for many scales
- Update CULDATA block to match rubberized membrane waterproofing standard drawings
Solution:
Updated the blocks to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\08-STRUCT.dwt
Issue: Structures – New Blocks
- DECK_POLYMER_TRANS – Section through polymer overlay transition at abutment joints
- WALL_SECTION – Typical section through MSE wall
Solution:
Added new blocks requested
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
-
C:\WisDOT\Stnd\C3D2022\AppData\ToolPalette\Sheets\08\Palettes\07-Super.atc
-
C:\WisDOT\Stnd\C3D2022\AppData\ToolPalette\Sheets\08\Palettes\11-Misc.atc
Issue: Structures – Table Imports
There is an inconsistent issue with OLE tables not coming in at the correct scale. In general, OLE tables can be difficult or tedious to import.
Solution:
Added a new tool to allow users to copy and paste directly from spreadsheets to C3D tables.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDot.Bos.Acad.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDot.Bos.Drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDot.Bos.Geometry.dll
- C:\WisDOT\Stnd\C3D2022\AppData\ToolPalette\Sheets\08\Palettes\01-Templates.atc
- C:\WisDOT\Stnd\C3D2022\AppData\ToolPalette\Sheets\08\Palettes\02-Anno.atc
2023-05-03
Issue: Batch Surface Profile Tool
In intersection design, it takes time to create surface profiles.
Solution:
New tool to batch create surface profiles from multiple alignments.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Retire Rebuild Surfaces Command
With the introduction of the “Rebuild out of date items” for surface objects in the Prospector, the Rebuild Surfaces Command is obsolete.
Solution:
Remove DOTRebuildSurfaces command.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\Wiribbon24-1.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1_light.dll
Issue: Area & Length report command information enhancement
User feedback is that these tools are not intuitive for finding quick areas/lengths.
Solution:
Dynamic total lengths/areas text added to the interface. As objects are selected, the text on the UI is updated. Changes to the precision settings and units (areas report) also dynamically update the running total display. Clicking on the displayed total copies the value to the system clipboard for use in other applications. The label areas function in the areas report has been separated from the create report function. A separate label areas button is now provided.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Control Profile Editor: Show transition rate
Users request the ability to see the rate of transition between control profile PVIs. This is useful for making sure transition rates are not extreme.
Solution:
Read-only column added to the profile edit grid that displays the rate of transition (i.e. slope ahead) between the profile PVIs.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Load XRef on Layer: Add layer locking
Need a way to avoid accidental moves, deletes and scaling of XReferences.
Solution:
Add layer locking to the “Load XRef on Layer” and “Assign XRefs to Layer” commands.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
Issue: Add gaps to earthwork calculations
Civil 3D has to ability to include gaps in the earthwork quantities (example: bridge projects). However, the WisDOT earthwork detail report ignores the gaps.
Solution:
Update the Earthwork Detail Report to include the gaps specified in Civil 3D.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Request from users to masks to sign blocks
Current sign blocks do not have masks and they have to be added if white space is not found in the plan sheet.
Solution:
New right click menu option added to block references. Select one or many block references, right click and choose “Add/Update mask”. Can also run from command line DOTMaskBlock. A filled MPolygon object is created behind the selected block reference(s). The MPolygon is placed on the WisDOT "P_MISC_Mask" layer. Layer is created if it does not exist.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1_light.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\Wiribbon24-1.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Purge unused references tool
Drawings can become bloated with many references that are not needed or used. Need a quick way to identify and remove unused references.
Solution:
New command DOTPurgeUnusedReferences presents the user with a list of XReferences, and a list of unused Data References in a TreeView. The user chooses references to purge. The tool also identifies any surface profile data references in the drawing as a reminder that the best practice is to avoid data referencing surface profiles to avoid circular references.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Design Surface Data Extractor: Extract from Corridor Surface
When the input surface is a corridor surface, the Design Surface Data Extractor does not extract the break lines. Only the boundary is extracted.
Solution:
Update the Design Surface Data Extractor to recognize if the input surface is a corridor surface and extract the break lines.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\AcDesignSurfaceDataExtractor.dll
Issue: EC Block masks
Request to add a mask visibility state to all erosion control blocks.
Solution:
Mask visibility states added
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Drainage.dwg
Issue: Section Editor Viewport Configuration
The default section editor viewport configuration is set to four views.
Solution:
Set the default section editor viewport configuration to two horizontal, plan/section
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: Traffic Control Barricade Block Updates
Request to have an option to flip tiger stripes in the traffic control barricade blocks. Request to have a Type 3 with signage and no lights.
Incorrect wording on R11-3 Sign.
Solution:
Add Flip grip to barricade blocks to flip the tiger strips.
Rename **Type III Barricade with Signage** to **Type III Barricade with Signage and Lites**
Create a **Type III Barricade with Signage without Lites**
Update the R11-3 visibility state to match correct wording
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Workzone.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-4\Palettes\30-Detours.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\WZ-Signs.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\WIPaletteImages.dll
Removed Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Type III Barricade with Signage64.png
Issue: Sharrow Bike Arrow
WisDOT package does not include a bike shared lane symbol for pavement marking.
Solution:
Add the MBIKESHARED block to the Pavement Marking Palette. Also update MBIKES block and palette image to match the SDD.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkingSigning.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-6\Palettes\60-Pavement Marking.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\MBIKES64.png
New Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\MBIKESHARED64.png
Issue: Add more scales to CD speedsheet template
User request for more viewframes and layouts in the CD Speedsheet template.
Solution:
Added 10 view frames and layouts for each 1IN:5FT and 1IN:2FT scales.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\02-CD-SPSHT-wdot.dwt
Issue: TPP Title Sheet Notes-Update to match FDM
FDM fd-12-10.pdf (wisconsindot.gov) changed for TPP Title Sheet notes.
Solution:
Update the TPP Title Notes block to match the FDM.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-plats.dwt
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Plats.dwg
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\04-TPP-TITLE30-wdot.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\04-TPP-TITLE34-wdot.dwt
Issue: ROW Plat > Lines & Symbols > Parallel Offset: Incorrect File Path
Parallel offset button is path is searching for the wrong file in the 2020 directory.
Solution:
Update the file path to 2022.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\04\Palettes\30-Lines Symbols.atc
Issue: Update (circle, square, oval, hex) tag blocks used in multileaders to have masks
Current blocks do not have masks. Request to add masks.
Solution:
MPolygons/solids added to block definition so the tag multileaders are masked. MPolygon was placed on the P_MISC_Mask Layer.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Dimensions\Mleaderstyles.dwg
Issue: Update Station Increment Labels tool to handle station equations
The tool skips a segment of labels when a station equation introduces the stationing that goes back on itself creating two instances of the same station.
Solution:
Updated to handle station equation scenarios where stations can occur multiple times.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Update Layer P_MISC_Mask to color 249
Current layer uses color 255,255,255 and when used makes it hard to see objects in model space with black background (White objects over white mask)
Solution:
Color 249 in model space is a light maroon color and plots to PDF a gray that is almost white. The gray is mostly not noticeable. Updated all templates, dwgs, and layer states that contained this layer with this new color.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg_LayerList.csv
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-corridor.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-parcel.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-section.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-surface.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
Issue: Typical Section Template and Palette Style Updates
Old dimension and multileader styles in the Typical Section Speed sheet.
Solution:
Updated the typical section speed sheet to include updated dimension styles and multileader styles. Added a new 060-UNDERLINE and 070-UNDERLINE multileader style for typical sections to replace the outdated multileader style.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\TypicalSpeedSheet.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-2\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Components\Dimensions\Mleaderstyles.dwg
Issue: Update MQ and EW Speed sheets designer notes
Designer note included outdated workflows.
Solution:
Updated designer note to include link to updated workflows on the C3DKB.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\03-MQ-SPSHT-wdot.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\09-EW-SPSHT-wdot.dwt
Issue: Fix linetype palette command to not overwrite the current default linetype
The buttons on the Linetype palette that integrate the **dotdrawlinetypetoscale** is not setting the default linetype in the dwg back to “BYLAYER”.
Solution:
Fixed the dotdrawlinetypetoscale command to reset the default linetype to “BYLAYER”.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Add awareness to sheet palettes for users to add dimension styles
If the dwg does not contain the dimension styles, improper settings are used when the dimension style is selected from the palette.
Solution:
Add button to palettes to make users aware to add dimension styles prior placing dimensions.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Dims\Palettes\10-Dimension Styles.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-2\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-3\Palettes\20-Intersection Details.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-4\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-6\Palettes\10-Startup Main.atc
Issue: DOTROTATEANNOTOVIEWPORT doesn't rotate block attributes
Command rotates the block reference, but any associated attribute text is left at its original rotation.
Solution:
Command updated to rotate attribute text along with block reference.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Command to import multileader style and create multileaders
WisDOT palettes for Multileaders have the style definitions baked into the palette .atc files. This can result in the palattes getting out of sync with the Multileader source files.
Solution:
Create custom commands to create MultiLeaders. The command prompts for the style name and then starts the mleader command. If the style does not exist in the drawing, it checks the WisDOT style source dwg files and imports them.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Initializer.dll
Issue: Insert Assembly from WisDOT palette introduces drawing error
After inserting an assembly from the WisDOT palettes, a drawing error is shown when running audit.
Solution:
Updated the assembly dwgs that were being called by each assembly palette tool.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies*.dwg
Issue: Update SPEL Block
The SPEL block is built using two polylines and when used in a point object, is not snappable.
Solution:
Update the SPEL block to be built out of four lines instead of two polylines. The point styles (such as E Surf Spot Elevation) will now be snappable using a node snap.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-marker-xsection-symbols.dwt
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkerSymbols\MarkerSymbols.dwg
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-point.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: General Notes Blocks Corrections and Updates
Requests to adjust the new general notes blocks.
Solution:
Added project overview to standard Section 2 Order of Sheets
Removed Utility Emergency Contact Block from dwg and Palette
Updated block layers to P_MISC_Text and P_MISC.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\GenNotes.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\01\Palettes\General Notes.atc
Removed Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Emergency Contact64.png
Issue: Update Multileader Palette Buttons so most recent styles are used
Most multileaders on most of the WisDOT Sheets Palettes are out of sync with current multileader styles.
Solution:
All palette buttons updated with the new command to create WisDOT Multileaders - DOTDrawMultileader. Once the button is pressed, the tool checks the drawing for the specified multileader style. If it doesn’t exist, the style is loaded. Update multileader styles source DWG as well - new style "Perm Sign Note".
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Dimensions\Mleaderstyles.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\01\Palettes\Title Sheets.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-2\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-3\Palettes\20-Intersection Details.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-4\Palettes\30-Detours.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-5\Palettes\30-Storm Sewer.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-6\Palettes\60-Pavement Marking.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-6\Palettes\30-Permanent Signing.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-6\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-7\Palettes\10-Startup Main.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\05\Palettes\20-Plan-Profile.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\10-Multileaders.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\20-Title Sheet.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\30-Typical Section.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\40-Plan Sheet.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\50-Profile Sheet.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Multi-leaders\Palettes\60-Traffic Control.atc
Issue: Update TLE template wording
TLE Template currently states “Sheet Number”.
Solution:
Adjusted TLEMAPTITLEBLOCK block so it reads EXHIBIT instead of SHEET. Adjusted components to fit the longer word.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\04-TLE-MAP-wdot.dwt
Issue: Draw Floating Curve unhandled exception
Unhandled exception when using the Draw Floating curve command from a line with the OrthoMode set to 1.
Unhandled exception when using the Draw Floating curve command from a line and object snapping to the end of the line.
Solution:
Updated the tool to account for these scenarios.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: AE CPRC Bid items contain duplicate sizes
All apron endwall for culvert pipe reinforced concrete bid items contained duplicate diameter dimensions.
Solution:
Removed the extra dimensions.
Updated Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Data\Pay Item Data\United States\WisDOT\Items_2020.csv
-
C:\ProgramData\Autodesk\C3D 2022\enu\Data\Pay Item Data\United States\WisDOT\Items_2022.csv
-
C:\ProgramData\Autodesk\C3D 2022\enu\Data\Pay Item Data\United States\WisDOT\Items_2023.csv
Issue: Update Manhole blocks - components are not centered around insertion point
Report that the manhole blocks and components contained are not centered around the insertion point.
Solution:
Updated manhole block components to be centered around insertion point
-
MHO
-
MH
-
MH-EL
-
MH-SAN
-
MH-SS
-
MH-TEL
-
MH-UT
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-point.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-marker-xsection-symbols.dwt
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkerSymbols\MarkerSymbols.dwg
Issue: BG Assembly Updates
Incorrect width and slope parameters in Unpaved Shoulder Subassembly
Add assemblies for CG under Thrie Beam Transitions
Unpaved shoulder subassemblies in WisDOT BG-Profile Slope Control.dwg parameters out of order
Solution:
Updated Unpaved shoulder subassembly in WisDOT BG-Profile Slope Control.dwg with latest ShldGeneric subassembly.
Updated all UnpvdShld subassemblies to correct settings
-
Paved slope= 4%
-
Unpaved Slope = 10%
-
Parameter reference pavement strucutre thickness to nearest paved shld subassembly
-
Adjusted method to calculate adjacent lane slope = Outside Shldr and 4%.
-
Adjusted point codes to match 2018 version of subassembly
New Assemblies for Thrie Beam Transitions in full lane and rehab scenarios
-
Includes Curb and Gutter
-
Beam Guard - Thrie Beam Transition
-
Beam Guard - Rehab - Thrie Beam Transition
Updated CrdrTrgtAssgn-BeamGuard.csv to include new subassembly names.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Rehab-NoLane-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\60-WisDOT_BEAM GUARD-ASSEMBLIES.atc
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-BeamGuard.csv
New Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-Rehab-TBT-NoLane-Profile Slope Control.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT BG-TBT-Profile Slope Control.dwg
Issue: SurfaceStatistics property set updates
The SurfaceStatistics property set in “ref-property-sets.dwt is referencing the incorrect version of AutoCAD. Users need guidance on how to use this property set.
Solution:
Change the ‘ACADver’ property to a formula property so it can be updated at the property set level when the AutoCAD version changes. It is currently a text property, so it must be updated at the object level.
Include a Civil 3D ‘Note’ label (Surf_3DArea) example in the “ref-property-set.dwt” to demonstrate how to use the SurfaceStatistics property set in labels.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-property-sets.dwt
Issue: Create Alignments from BG block unhandled exceptions
When a folder already exists for the BG alignments, an unhandled exception occurs, and the alignments are not created.
Unhandled exception when alignment names already exist.
Solution:
Tool checks if folder already exist.
Tool checks if alignment names already exist and goes with next counter.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOT.Extensions.dll
Issue: Structures - Updated Blocks
-
Incorrect tables in DEFLECTION, SHEET_LIST, TANOFF, TOD
-
Added TABLE block for more easily creating generic tables
-
Added GT_BORING_TABLE block and removed the optional boring table from the GT_GRID block
-
Incorrect SHEET_PILE linetype
-
Separate ABUT_FILL block to add CULBF and WALL_BF blocks, and add fill behind culvert wing wall detail.
-
Error in geometry for the 56SS parapet in the BARRIERS block.
-
Update DESIGN_CONTACTS block for staff changes.
Solution:
Updated the blocks to be correct.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
Issue: Structures - File type
Error with file type tool not corrected last quarter.
Solution:
Updated the tool to remove the bug.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\ WisDot.Bos.Acad.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\ WisDot.Bos.Drafting.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\ WisDot.Bos.Geometry.dll
Issue: Structures - Updated Palette Images
Update tool palette to reference resource library instead of individual images.
Solution:
Updated the tool to remove the bug.
Updated Files:
-
\WiBOSPaletteImages.dll
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\02-Anno.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\03-General.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\04-Quan.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\05-Substr.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\06-Rebar.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\07-Super.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\08-Barriers.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\09-Steel.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\10-Culvert.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\11-Misc.atc
2023-01-25
Issue: Solution for scheduled batch plotting of DSDs
Need an efficient way to batch plot using multiple DSD files and the ability to schedule those plots to run at a specified time and recurrence.
Solution:
Publish Collections Manager (DOTPublishCollectionsManager) developed to manage and execute the plotting of multiple DSD files (Publish Collection).
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
New Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\BatchPublish.dll
Issue: Supplemental tools for AutoCAD drafting
Several gaps exist with out of the box AutoCAD draw tools.
-
Fillet: When creating a fillet between two arc or circle entities, the fillet direction cannot be chosen.
-
Draw Line tangent to Arc/Circle: This works with out of the box tools, but only to the extent of the arc. Need to draw a line tangent to the full circular projection of the arc.
-
Draw floating arc: Need to dynamically draw an arc tangent to lines, arcs, and circles while seeing it’s proposed position as the cursor moves.
Solution:
Create four new commands and add them as buttons to a new “Draw” panel on the WisDOT Design ribbon.
Ribbon buttons on the new Draw Panel:
-
WisDOT Design > Draw > Lines > Floating Line
-
WisDOT Design > Draw > Lines > Free Line
-
WisDOT Design > Draw > Curves > Floating Curve
-
WisDOT Design > Draw > Curves > Free Curve
Commands:
-
DOTDrawFloatingLine: Command prompts for an arc or circle entity. A preview of the line is drawn dynamically based on the cursor position. User selects the end point of the line to add the entity to the drawing.
-
DOTDrawFreeLine: Command prompts for two arc/circle entities. User is presented will all possible tangents between the entities. User selects the desire tangent to add to the drawing.
-
DOTDrawFloatingCurve: Command prompts for a line, arc, or circle entity and a radius for the proposed arc. A preview of the arc is draw dynamically based on the cursor position. The radius can be change while the command is active. User selects the end point of the arc to add the entity to the drawing.
-
DOTDrawFreeCurve: Command prompts for two arc/circle/line entities and a radius. User is presented with all possible curve options and can choose one to add to the drawing. The radius can be changed while the command is active.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1_Light.dll
Issue: Copy Assembly
Need a more efficient way to copy an assembly between two drawings.
Solution:
Added new command Copy Assembly to the Assembly object context menu. Added Assembly - Paste to Original Coordinates and Assembly - Paste commands to the Application default context menu.
-
Paste commands are only visible when an assembly has been copied.
-
One paste per copy allowed.
-
Option to specify for a new name for the pasted assembly is provided.
-
New assembly will use the original code set style assignment if it is available.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: General Notes Upgrades
Request from NE and NC regions to enhance the General Notes Palette with more standardized blocks, text, and general notes.
Solution:
Create new blocks, notes, and objects for the palette.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\NotesTables.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\plansht.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\cdErosionControl.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\cdErosionControl.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\01\Palettes\General Notes.atc
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
New Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\02-GN-SPSHT-wdot.dwt
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\GenNotes.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Miscellaneous Contact64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Survey Coordinator Contact64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\County Highway Commissioner Contact64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\City-Town Contact64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Design Project Manager Contact64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Design Leader Contact64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\DNR Contact64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Emergency Contact64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Utility Contact64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Utility Header64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Paving Table64.PNG"
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Order of Sheets64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\General Notes Header64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Standard General Notes64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Standard Abbreviations64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Diggers Hotline64.PNG
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Runoff Coefficient Table64.PNG
Removed Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\GN Utility Contact Format64.PNG
Issue: Create a Clear Zone Width from profile target parameter for sub DaylightProfileControlled and a Recoverable distance from profile target parameter for sub CutFillProfileControlled
Controlling the location of the slope break between recoverable and non-recoverable slopes (clear zone/recoverable width) would be easier with a control profile than editing a horizontal target object.
Solution:
Added new “Clear zone width from profile” elevation target to DaylightProfileControlled.
Added new “Recoverable distance from profile” elevation target to CutFillProfileControlled.
Updated Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.cfg
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.dll
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.emd
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.pvd
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CutFillProfileControlled\e31774a1f6be4f37ae4b8c2a88d90fa5.xaml
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.cfg
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.dll
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.emd
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.pvd
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\DaylightProfileControlled\c8544c3853224aabb4e5311832173a93.xaml
Issue: Input CSVs updated related to adding Clear Zone width from profile to DaylightProfileControlled sub
Solution:
Add parameters to input CSVs for Create Control Profiles in Control Profile Editor and Set Corridor Target tools
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\CreateSlpCntlProfs.csv
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\CreateSlpCntlProfs-ReturnFillet.csv
- C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-BeamGuard.csv
- C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-FilletReturn.csv
- C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-FullSection.csv
Issue: Fix ProfileToParameterRef default output values
The ProfileToParameterRef subassembly does not use the input values as an output value for the referencing subassembly when in layout mode.
Solution:
Update the ProfileToParameterRef subassembly so the input values are used as the default output parameter reference value for the consuming subassembly.
Updated Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\ProfileToParameterRef\3d662*
Issue: Plat Palette button does not work
On the ROW/Plat Palette > Non-TPP Tab. The O4-PLAT-Title button does not work.
Solution:
Command updated to point to the correct file.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Intersection Assemblies - Update Returns to remove crown point Codes - Add Sideroad CL Assembly
The intersection assembly for curb returns have the lane not inserted properly. Also, there is not a standard assembly for the Sideroad Centerline.
Solution:
Update the lane subassembly so the crown is on the outside and there are no Crown point codes. Add a Sideroad CL assembly.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Curb Return Fillet.dwg
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Shoulder Return Fillet.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\70-WisDOT_INTERSECTION-ASSEMBLIES.atc
New Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\WisDOT Sideroad CL.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\Sideroad CL.png
Issue: Erosion Control Legend - Culvert Pipe Check Correction
The erosion control legend has the culvert pipe check incorrectly named: “Culvert Pipe Ditch Check”
Solution:
The block was updated to the correct name: “Culvert Pipe Check”
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Drainage.dwg
Issue: Create Superelevation Profiles does not run
Unhandled exception when attempting to run Create Superelevation Profiles.
Solution:
Fixed issue where application attempts to populate data grid before necessary rows are established.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: CDP Integrity Report - Read zip subfolders within a zip folder
Data Referenced alignments should not be listed since they are read-only.
Solution:
Filter out Data Referenced alignments so they no longer show in the list of alignments.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Remove DRef alignments from Superelevation Runout lists
DRef’d alignments should not be listed since they are read-only.
Solution:
Filter out DRef’d alignments so they no longer show in the list of alignments.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Lengths Report/Areas Report unhandled exception with no alignments in drawing
Lengths report does not support lines, arcs, circles, or ellipses. When quick total option is used for these reports, the value must be transposed to the destination.
Solution:
Support for lines, arcs, circles, and ellipses added to the Lengths Report. When the quick total option is used for the Areas Report/Lengths Report, the resulting value is now added to the clipboard so it can be pasted to the desired destination.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Areas Report/Lengths Report enhancements
Lengths report does not support lines, arcs, circles, or ellipses. When quick total option is used for these reports, the value must be transposed to the destination.
Solution:
Support for lines, arcs, circles, and ellipses added to the Lengths Report. When the quick total option is used for the Areas Report/Lengths Report, the resulting value is now added to the clipboard so it can be pasted to the desired destination.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Survey Database Settings file update to fix figure edit crashes
Issues with making edits to survey figures in SSD leads to crashes in some situations.
Solution:
Set the default for the Logging Enabled for Change Reporting setting to NO in the settings file. This will turn off logging of changes when making changes to survey entities and committing them to the database.
Updated Files:
C:\ProgramData\Autodesk\C3D 2022\enu\Survey\WisDOT Survey Database Settings.sdb_set
Issue: Add Create Corridor Surfaces input CSV for roadway and curb returns
Create an additional CSV for automatically creating corridor surfaces for setup corridors.
Solution:
New CSV file added that uses the link codes Top, Norm, Min, and Max to create each surface.
New Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\CreateSetupSurfs.csv
Issue: Sync Project Files: ACC compatibility
The command DOTSyncProjectFiles does not work with projects on ACC. Two issues are known:
-
ACC file paths are per user, so if a different user tries to load the file/object list CSV, an error occurs.
-
An error occurs when a drawing save is attempted via the .NET API.
Solution:
-
When loading a CSV that contains user-specific paths, the paths are now converted to the current user path for that session.
-
Drawing save is now performed by sending the QSAVEcommand to the command line. This change has only been tested for Desktop Connector 16.0 and newer.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: DWG Clean: ACC compatibility
The command DOTDrawingClean does not work with files on ACC. An error occurs when a drawing save is attempted via the .NET API.
Solution:
Drawing save is now performed by sending the QSAVEcommand to the command line. This change has only been tested for Desktop Connector 16.0 and newer.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Add type TBT curb head for 30-inch and 36-inch, add Types R and T to 30-inch
There appears to be a new curb head type TBT that can be for both 30-inch and 36-inch curb and gutter that need to be added. Currently in the CGBasic sub, both R and T are assigned to 36-inch. They need to be added as options to the 30-inch group also.
Solution:
Type R and T have been added as options to the 30-inch group.
New Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic2.
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\10-WisDOT_ROADWAY.atc
Issue: Input CSVs updated related to adding Clear Zone width from profile to DaylightProfileControlled sub
Solution:
Added parameters to input CSVs for Create Control Profiles in Control Profile Editor and Set Corridor Target tools
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\CreateSlpCntlProfs.csv
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\CreateSlpCntlProfs-ReturnFillet.csv
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-BeamGuard.csv
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-FilletReturn.csv
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-FullSection.csv
Issue: Structures - Updated Blocks
-
Update ABUT_FILL block to correct typos, remove recursive blocks, and adjust dimension pointing to incorrect location.
-
Update CULINLET to align with standard details.
-
Update DECK_SECTION to allow stacked fractions.
-
Update DESIGN_CONTACTS block for staff changes.
-
New blocks: PS_GIRD_PLAN, BAR_SIZES
Solution:
Updated the blocks to be correct.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\02-Anno.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\03-General.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\06-Rebar.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\07-Super.atc
Issue: Structures – Add Dimension Style
Request for a dimension style that uses decimal-feet for design sketches.
Solution:
Added a new dimension style named “Decimal” and a shortcut to this style in the tool palette.
Updated Files:
-
C:\WisDOT\Stnd\ C3D2022\Templates\Begin-dwg\struct-decimal-start.dwt
-
C:\WisDOT\Stnd\ C3D2022\Templates\Begin-dwg\struct-inch-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\02-Anno.atc
2022-11-02
Issue: Control Profile Editor: Default CSV access
Need more convenient access to the WisDOT default CSV.
Solution:
Added a button to to open the WisDOT default CSV (read-only) in the default CSV editor. User can "Save As" the CSV to a desired location for further editing.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Point Station/Offset to UDP rebuild
Incorporate multiple user requests to the Point Station/Offset to UDP tool.
Solution:
Tool rebuilt with the following enhancements:
-
Adds USWI Alignments UDP to drawing if it does not exist.
-
If a point is coincident with the center of curve for any curve in the drawing, the radius value is populated.
New command name is DOTPOINTSOUDP.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTCivil3DExtensions.dll
Issue: Control Profile Editor: Allow '%' value entries
The Control Profile Editor automatically interprets entries that contain ':' as X:1 slope and converts the values to ft/ft. Option requested to enter values with a '%' and convert those to ft/ft.
Solution:
Control Profile Editor enhanced to allow values entries that contain '%'. These values are converted from percent to ft/ft.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Control Profile Editor - Copy PVI(s) from one profile into another
Need a way to copy profile PVI(s) from one control profile to another.
Solution:
Right click menu option added for the edit control profile grid.
Menu command copies selected PVI(s) from the active profile to another control profile with the same parent alignment. This function will not overwrite PVI stations that already exist under the destination control profile. Menu is not available if only one control profile exists under the alignment.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Create profile from points
An automated process is needed to create a profile from point data. This tool will benefit the Check Profile Sight Distance analysis which is intended to be used when limited design data is available.
Solution:
New tool created DOTCreateProfileFromPoints. Tool uses points in a Point Group to develop a profile.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Updated SetCrdrTargets input CSV for Beam Guard
There was an error in the setting of paved shoulder feature line in the area of beam guard.
Solution:
Correct the input CSV for beam guard.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Assemblies\CrdrTrgtAssgn-BeamGuard.csv
Issue: Apply Layer State
An enhanced method for applying layer states is needed to include XReference layers when applying a layer state.
Solution:
New tool "Apply Layer State" added. Access is via command line DOTApplyLayer or via the Layer Colors Manager. The Apply Layer State tool applies the selected layer state to the active drawing, with the option to apply it to any corresponding XRef layers and save the layer state with the corresponding XRef layers.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
Issue: Layer Colors Manager
Incorporate several enhancement ideas into the Convert Layer Colors tool.
Solution:
Convert Layer Colors tool rebuilt and renamed to "Layer Colors Manager". Command is DOTLayerColorsManager. Changes include:
-
Add layer colors to the grid view.
-
Grid view sortable by layer or color
-
Add same layer selection controls as Layer Properties Manager
-
Tool reactive to changes in drawing
-
More compact design
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
Issue: Fix MultiProfToParameterRef default output values
The MultiProfToParameterRef subassembly does not use the input values as an output value for the referencing subassembly when in layout mode.
Solution:
Updated the MultiProfToParameterRef subassembly so the input values are used as the default output parameter reference value for the consuming subassembly.
Updated Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\MultiProfToParameterRef\*.*
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\30-WisDOT_GENERAL SUBASSEMBIES.atc
Issue: Change DRef Surface Storage
Currently when a data reference surface is created the geometry is stored in a drawing. There is a command setting which controls whether the geometry of reference surfaces is saved in the drawing.
Solution:
Changed the command setting which controls whether the geometry of reference surfaces is saved in the drawing to NO.
The geometry of reference surfaces will not be saved in the drawing. When set to NO, the reference is checked every time the drawing is opened. The drawing will be smaller and save faster but will open more slowly.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\x-wisdot.dwt
Issue: Excel Add-in: Create multiple instances of header cells
It is difficult to fit long tables onto plan sheets. They often need to be broken up. Need to insert header rows multiple times in long tables so they can span multiple plan sheets.
Solution:
Created an Excel Add-in tool to replicate selected cells at a specified frequency of rows. "Repeat Selection Every ___"
Updated Files:
-
WisDOTC3DExcelAddinSetupx64.msi
-
WisDOTC3DExcelAddinSetupx86.msi
Issue: Add WisDOT default paths to the AutoCAD Block Library palette tab
The AutoCAD INSERT Blocks palette Library tab does not have the WisDOT default paths added.
Solution:
Added the WisDOT default paths to the Block Library. A profile reset may be required to see the changes.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\2022wisdot.arg
Issue: New standard size manholes
2023 spec book includes standard 9-FT and 10-FT manholes. These are not currently included in the WisDOT Civil 3D storm sewer parts list.
Solution:
-
Added 9-FT and 10-FT manholes to the Storm Sewer parts list.
-
Removed the 10-FT sizes from the Non-Standard parts list.
-
Added 9-FT manhole to parts catalog.
-
Added 2023 Spec year pay item files
-
Mapped start templates to 2023 spec year pay item files
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Structures_USWI\USWI Manholes\USWI_Cylinder_Manholes 3-8.xml
-
C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Structures_USWI\USWI Inlets\Type C Covers\USWI_Cylinder_Manholes 3-8_C.xml
-
C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Structures_USWI\AeccSharedPropertyLists.xml
-
C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Structures_USWI\Structures_USWI.apc
-
C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Structures_USWI\Validate\Catalog_Regen_Summary.txt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
New Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Data\Pay Item Data\United States\WisDOT\Categories_2023.xml
-
C:\ProgramData\Autodesk\C3D 2022\enu\Data\Pay Item Data\United States\WisDOT\Items_2023.csv
Issue: Pavement marking layers: Correct layer settings
The layer settings for the majority of the pavement marking layers are incorrect.
Solution:
The layer settings were corrected to Pre-2020 standards.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg
Issue: Update WisDOT Standard table size margins
Initial release had 0.03 margins on all cells.
Solution:
Update to 0.02 vertical and 0.01 horizontal to minimize cell size.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Tables\Tables.dwg
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\03-MQ-SPSHT-wdot.dwt
-
C:\WisDOT\Stnd\C3D2022\Templates\Sheets\09-EW-SPSHT-wdot.dwt
Issue: Label Assemblies tool causes C3D crash
When using the Label Assemblies command from the Assembly right click menu, Civil 3D crashes.
Solution:
Code revised to avoid C3D crash.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Palette image consolidation
There are many palette image files that are duplicated because they are used on multiple palettes. There are also many palette image files that are no longer used.
Solution:
Created a shared palette image directory. Re-mapped palette ATC files to the shared image directory. Removed image files that are no longer used. Used built-in Autodesk images wherever possible. For blocks, used a single image for dark/light modes.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\*.atc
New Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Images\*
Removed Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\ (various unused files)
Issue: Alignment Description Report Save Error
The Alignment Description Report produces a file save error. The report is created, but it is not automatically saved.
Solution:
"Save as" path repaired to eliminate error.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: PDFSHX system variable
Some PDF outputs have comments created where there should be text.
Solution:
Set PDFSHX = 0 at application startup for WisDOT devices. External users can apply WisDOT-specific settings using DOTSETWISDOTVARIABLES.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Superelevation Report: Stations out of alignment range
Occasionally, an alignment superelevation definition may contain stations that are outside of the alignment range. The WisDOT superelevation report does not run in this scenario.
Solution:
WisDOT superelevation report modified to handle superelevation data that is outside of the alignment range.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: BG EAT R Left Curve block pavement edge graphic issue
Adjusting the radius to the BG EAT R Left Curve block pavement edge shows a full circle.
Solution:
Updated the BG EAT R Left Curve parametric block to not show extraneous graphics when modifying the radius.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-eat.dwg
Issue: BG EAT note linetypes set to ByLayer instead of Continuous
Note lines for post offsets and radius were set to ByLayer. If these blocks were put on a beam guard type layer they inherited that linetype.
Solution:
All note object linetypes were set to Continuous.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-eat.dwg
Issue: BG EAT paved shoulder goes out of range
The paved shoulder polyline could become corrupt depending on edits made.
Solution:
Grips were removed and a maximum value set to distTotaltoPavedShldrto eliminate problems.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-eat.dwg
Issue: Add type TBT curb head for 30-inch and 36-inch, add Types R and T to 30-inch
There is a new curb head type TBT that can be used for both 30-inch and 36-inch curb and gutter.
Currently in the CGBasic sub, both R and T curb head types are assigned to 36-inch. They need to be added as options to the 30-inch group.
Solution:
Added type TBT curb head for 30-inch and 36-inch, added Types R and T to 30-inch
Updated Files:
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.atc
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.cfg
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.dll
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.emd
-
C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.xaml
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Wis-A-Sub-Assemblies\Palettes\10-WisDOT_ROADWAY.atc
Issue: CDP Integrity Report: Remove check for Contractor Feedback
The Contractor Feedback Form has been removed from the CDP. It is now given to the contractor via a web survey.
Solution:
Remove the check for the Contractor Feedback form.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Assign Corridor Targets tool Unhandled Exception
Assign Corridor Targets tool sometimes gives Unhandled Exception errors when starting.
Solution:
Error resolved.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Set Linetype to Continuous for all blocks in the Beam Guard Detail tool palette
The beam guard detailed hardware component blocks obtained their linetype setting from the current layer on insertion from the palette. This resulted in undesired linetypes when placed on beam guard layers.
Solution:
All blocks in Beam Guard Detail tool palette have linetypes set to Continuous. They will now display correctly when placed on layers with beam guard linetypes.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-dtl.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Design\Parametric\BeamGuard\Palettes\20-Beam Guard Detail.atc
Issue: Rename DOTResetWisDOTProfile
The name of this command and its description is not accurate. The command actually deletes the current profile. It does not have to be a WisDOT profile. It will not delete the <<C3D_Imperial>> profile.
Solution:
Command name and description edited to reflect the actual functionality. New command name is DOTRemoveCurrentProfile. Added warning when running the command indicating that the current profile will be removed and Civil 3D will exit.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
Issue: Structures - Updated Blocks
-
PPT_TRANSITION had incorrect width at end of transition.
-
Typos in CULV_JT and RODENT blocks.
-
Added additional slope detail to ABUT_FILL
-
Update DESIGN_CONTACTS block for staff changes.
-
New blocks: WALL_NOTES, BAR_LAP, SLAB_SECTION and SLAB_SECTION_NOTCH
Solution:
Updated the blocks to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\06-Rebar.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\07-Super.atc
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\11-Misc.atc
Issue: Structures –Culvert Palette
The Apron Joint detail gives the detail for joints between barrels.
Solution:
Update Culvert Palette to correct blocks.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\10-Culvert.atc
Issue: Structures –TemplatesPalette
Missing ability to import standard Structures layers, and difficult to check a file to see if it follows the standards in the Structures templates.
Solution:
Added two new tools to the Templates Palette:
-
Import Structures Layers tool will import any missing standard structures layers and correct any non-standard settings in existing structures layers.
-
Check Drawing Type tool will check the drawing’s settings and let you know if it is set up as a structures layout file (decimal-ft), a structures details file (architectural-in), or if the file has bad settings and may cause errors.
Updated Files:
-
C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\01-Templates.atc
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.acad.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
Issue: Structures –Breakline Tool
The Breakline tool on the annotation palette would not scale correctly when an annotative dimension style was being used. The tool would crash if it was used in an invalid drawing file.
Solution:
Updated the tool to correct these errors.
Updated Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.acad.dll
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
2022-08-31
Issue: Update WisDOT Design Criteria 2009.xml
According to the WisDOT FDM/SDD Transmittal 424 Update Notification – May 17, 2022, the sight distances standards have been updated to reflect those listed in a more current version of the AASHTO Green Book Edition 2018.
Solution:
Revise file to match FDM update which is based on 2018 Policy on Geometric Design of Highways and Streets standards.
- Update Categories
- Add additional design speed standards
- Update passing sight distances
Updated Files:
- C:\ProgramData\Autodesk\C3D 2022\enu\Data\Corridor Design Standards\Imperial_WisDOT Design Criteria 2009.xml
Issue: Add New Roadway Access Control lines to ROW/Plat palette
New Roadway Access Control lines missing from R/W Palette. Layers and linetypes exist, only need to create palette buttons.
Solution:
Add buttons for Access by New Project Line (Triangles) and Access by New Project Segment Line (Triangles) on the ROW/PLAT Palette.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\04\Palettes\30-Lines Symbols.atc
Issue: Assign Page Setup
Code consolidation. Some functions are not needed for the Multi-page setup tool
Solution:
Tool redeveloped. New command DOTAssignPageSetup
- Removed "Show model space in Layouts" checkbox. Model space is automatically excluded
- Change page setups selection to a combo box.
- Added help button
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\MultiPageSetup.dll
Issue: Control Profile Editor Rebuild
Multiple enhancement request.
Solution:
Public summary of the solution developed.
- Add to Alignment right click menu
- Open to "Edit" tab if control profiles exist. Open to "Create" tab is no control profiles exist.
- Only display control profiles that do not include curves
- Only display alignments on the edit tab that have ZCP profiles
- Eliminate "Remove" tab
- Allow elevation entries as ft/ft or x:1.
- Full station equation support, including when stations occur multiple times
- Allow station edits in data grid view
- Add style choices for profile style and label set style
- Auto profile update when editing table
- Auto-populate profile view name, but remain editable
- Display option to choose which profiles to create in CSV
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SlopeControlEditor.dll
Issue: Swap Parts not functioning
The WisDOT swap multiple pipe network parts tool is not functioning. It does not read the drawing parts lists.
Solution:
Redevelop tool with new command DOTSwapParts.
-
Parts can be swapped by multiple methods.
- Preselect all parts to be swapped (must be all structures or all pipes). Then run the command. Command can be accesses with the right click menu, button on ribbon tab, or command line.
- Run the command and then choose to select structures or pipes.
-
All available parts lists are presented in a tree view. The desired part is selected from the tree view.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SwapParts.dll
Issue: Swap Parts List Styles
Code consolidation.
Solution:
Tool redeveloped for consistency for other WisDOT tools. New command DOTSwapPartsListStyles
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
Issue: Adjust Superelevation Runout
Code consolidation
Solution:
Tool redeveloped for consistency for other WisDOT tools. New command DOTAdjustSuperelevationRunout
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SEUpdate.dll
Issue: Remove Earthwork "Beta" label
No further user feedback has been received on the new earthwork reporting tools.
Solution:
Remove the "Beta" label on the new earthwork reporting tools.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- WisDOTC3DExcelAddinSetupx86.msi
- WisDOTC3DExcelAddinSetupx64.msi
Issue: Sight Distance: 2D analysis
A non-AutoTURN option is needed for the "quick" 2D Sight Distance analysis on profiles.
Solution:
Provide new tool for analyzing sight distance on Civil 3D profile options. DOTCheckProfileSightDistance
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
New Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_CheckProfileSightDistance.png
Issue: Set Text Style/Size rebuild
The Set Text Style/Size tool is not functioning properly.
Solution:
Rebuild the tool. New command DOTSetTextStyle. Remove former command. Improvements include:
- Load WisDOT text style when initializing tool
- Bi-directional connection with AutoCAD TextStyle and TextSize variables.
- Added MText button
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTCivil3DExtensions.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SetTextSize.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\SetTextSize.ini
Issue: Design Surface Data Extractor and ACC
The Design Surface Data Extractor fails to run on projects kept on ACC.
Solution:
Updated the Design Surface Data Extractor to use the new Civil 3D Data Shortcut API. Removed the input for the Data Shortcut project folder since it is no longer needed. Updated the palette behavior at startup.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\AcDesignSurfaceDataExtractor.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\AcDesignSurfaceDataExtractor.dll.config
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTCivil3DExtensions.dll
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\AcDesignSurfaceDataExtractor.xml
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\AcDesignSurfaceDataExtractor.resources.dll
Issue: Structure Sump Adjust
Code consolidation. Improved access and ease of use for the Sump Adjust tool is needed.
Solution:
Tool redeveloped. New command DOTAdjustSumps
- Removed UI and moved to command line
- Command can be accessed from the ribbon or the structure right click menu
- Structure selection is more flexible. Can select all or individual using command prompt. Pick-first options added to allow selection on screen or using Toolspace-Prospector.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
Removed Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SumpAdjust.dll
Issue: Lengths Report, Areas Reports, 3D Surface Area Report : station format
Users' request easier access to station values in the reports.
Solution:
Separate begin and end station values into separate columns. Keep station values as numbers and use Excel formatting to include the '+' character.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Areas/Lengths Report: Include object Layer
The object layer is needed to help sort out the resulting quantities in the report
Solution:
Add a column to report the object layer.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Earthwork Detail Report: Ability to delete columns
The formulas created in Excel by the Earthwork Detail Report include dependencies on columns that are often deleted because they are not used on all projects. If these columns are deleted, the downstream formulas no longer function.
Solution:
Implement the IFERROR() function in Excel formulas that are downstream of columns that are frequently deleted.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Update Earthwork Template.xslx
Formatting of earthwork template - details - resulted in unwanted cell borders on portions of the Mass Ordinate Column due to the proximity of that column to the notes. Real Station does not wrap. Confusion on if 3rd column of notes on detail sheets are required for plan sheets. Some cells need to be merged for use with the C3D Datalink>Table workflow.
Solution:
Bundle and Apps Versions: Move the notes to Column Y to add separation between Mass Ordinate Column and the notes. Change Cell B2 (Real Station) to Wrapped Text. Modified formatting of 3rd column of Detail Notes to reflect they are designer notes.
Bundle Version only: Detail sheet merged/Left Align cells A1:M1. Merged/Left aligned each row of the Ewk Summary Notes cells. Update Cell D8 of Earthwork Summary Template to warn users to delete the un-needed row if EBS column is deleted.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\Earthwork Template.xlsx
- C:\WisDOT\Stnd\Apps\Earthwork Template.xlsx
Issue: Rename MQ_Named Range
There is a misunderstanding over the purpose of this tool due to the "MQ" prefix. The purpose of the tool is to create easily distinguishable named ranges for data linking in AutoCAD. It can be used for any data linking purpose, not just for miscellaneous quantity tables.
Solution:
Rename tool to "Data Link Named Range". Change named range prefix to "DL".
Updated Files:
- WisDOTC3DExcelAddinSetupx86.msi
- WisDOTC3DExcelAddinSetupx64.msi
Issue: Add WisDOT Parts Lists button not working
The Add WisDOT Parts Lists button is not working.
Solution:
The button is calling an unknown command. It should be calling DOTAddWisPartsLists.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
Issue: Shrink Wrap Corridor Surface - Boundary creation error
DOTShrinkwrapCorridorSurface returns a boundary error when the corridor has multiple regions and at least 1 region has a single isolated station that includes the boundary point codes. The error occurs because a polygon boundary can not be defined by less than 3 points.
Solution:
Instances where where the defining point codes occur at a single isolated station are now ignored.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Remove styles for Sight Distance analysis for 6-in object
According to the WisDOT FDM/SDD Transmittal 424 Update Notification – May 17, 2022, the sight distances standards have been updated to reflect those listed in a more current version of the AASHTO Green Book Edition 2018.
- Standards involving a 6-in object height have been removed
- Category 3 has been removed
Solution:
Remove styles: Profile > Profile Styles > SD Available Sight Distance 6in Update style:
- Rename Profile > Profile Styles > SD Available Sight Distance 24in to SD Available Sight Distance
- Rename Profile View > Band Styles > Profile Data > Distance Left (24in Object Height) to Distance Left (Available Sight Distance)
- Rename Profile View > Band Styles > Profile Data > Distance Right (6in Object Height) to Distance Right (Stopping Sight Distance)
- Profile View > Band Styles > Band Sets > Sight Distance use renamed Profile data
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: WisDOT Ribbon Icon Clean-up
There a many legacy icons that are no longer used. Some icons appear blurry.
Solution:
Consolidate redundant images and use stock images where possible. Remove images that are no longer in use.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\Bulldozer.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\ExcelLogo3DataLink.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\layers_map.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_RebuildSurfaces.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_paletteRCDATA2doptim.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\trello-logo.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
New Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\Wiribbon24-1.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1_light.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\WIS_EXPORT.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\RCDATA_SCHEDULE_TABLE_EXPORT_16.bmp
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\RCDATA_SCHEDULE_TABLE_EXPORT.bmp
Removed Files:
-
C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons
- Various images
Issue: CGBasic subassembly - control profile for curb height
The current CGBasic subassembly does not allow for control profile targeting of the curb height when the attachment point is the top back of curb.
Solution:
CGBasic modified to allow for control profile targeting of the curb height and manual curb height override when the attachment point is the top back of curb.
Updated Files:
- C:\ProgramData\Autodesk\C3D 2022\enu\Imported Tools\CGBasic\1fbae749c07644d9892c9b3be42ac296.*
Issue: Shrinkwrap Corridor Surface (DRef Corridors)
The Shrinkwrap Corridor Surface command does not work on corridor surfaces that are created from a data reference corridor.
Solution:
Removed the point validation that utilized the source corridor assemblies.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Update name of MQ Table Style to avoid confusion
It is possible that the current MQ Table Style name would introduce confusion into users assuming the table style must only be used for miscellaneous quantities.
Solution:
Update the table style name to WisDOT Standard Modified the Create Data Links and Tables to use the WisDOT Standard as the default style. Added a refresh table style list button to allow users to import tables styles using the DOTAddWisTableStyles command while keeping the Create Data Links and Tables dialog open.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\03-MQ-SPSHT-wdot.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\09-EW-SPDSHT-wdot.dwt
- C:\WisDOT\Stnd\C3D2022\Components\Tables\Tables.dwg
Issue: Enable Rotate View command in Layout
User requests ability to use the Rotate View command when Model is the active space in a Layout.
Solution:
Rotate View enabled when layout viewport active space is Model. Note that cursor will remain oriented with the view. Use the Align Viewport command to keep cursor oriented with WCS.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Load Xref on Layer scaling issue
When inserting xref set to a specific unit (inches, feet, etc.) into a drawing set to unitless, xref is scaled in meters.
Solution:
If xref or host dwg is set to Unitless, Force xref scale = 1
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Reset WisDOT Profile command error/Restore User Settings not working
Command does not reset the profile. A message states "Profile cannot be reset". Restore User Setting command does not work.
Solution:
Repaired Rest Profile command to correctly reset the current profile. Repaired Restore User Settings to correctly save user setting upon C3D exit.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Updates and fixes to survey point styles
Some survey point styles contain incorrect scales. Survey template is missing some point style references.
Solution:
The description keys contain many point style dependencies that were turned off in group-survey.dwt. Turned on all point styles under "reference template defaults" in group-survey.dwt. Updated and corrected P_XS_Rock point style.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-point.dwt
Issue: WisDOT Mass Ordinate shape styles not assigned
WisDOT Mass Ordinate quantity take off criteria should have shape styles assigned to each criteria.
Solution:
Assign the appropriate shape styles
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
Issue: Update SSD multileaders
According to the WisDOT FDM/SDD Transmittal 424 Update Notification – May 17, 2022, the sight distances standards have been updated to reflect those listed in a more current version of the AASHTO Green Book Edition 2018.
- Category 3 has been removed
Solution:
Remove reference to "Minimum/Upper Minimum" in multileaders
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\Sight\Palettes\10-SIGHT DISTANCE.atc
- C:\WisDOT\Stnd\C3D2022\Components\Dimensions\Mleaderstyles.dwg
Issue: Create Typical from Assembly missing text
When choosing a vertical exaggeration of 1, the Create Typical from Assembly tool does not produce the text for slope labeling.
Solution:
Tool repaired to include text at all vertical exaggerations.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Set SSMAUTOOPEN to 0
Current default setting is for SSM to always open when a drawing that is associated to a sheet is opened.
Solution:
Change the default to not open SSM automatically when a drawing associated with a sheet is opened. Set variable SSMAUTOOPEN = 0
This default setting is not persistent with a Civil 3D startup and may be changed by the user. Running the profile reset tool will set the SSMAUTOOPEN variable back to 0.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\2022wisdot.arg
Issue: DOTSetWisDOTVariables: Include WisDOT internal variables
The DOTSetWisDOTVariables command only sets the universal variables set by the WisDOT extension. Need to include the variables set for WisDOT internal devices. This will enable external users to more closely replicate the WisDOT internal setup, if desired. The DOTSetWisDOTVariables command does not indicate which variables are set.
Solution:
Included both the universal and WisDOT internal variables in the command. Variables that are set are printed to the command line.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Annotation palette: Add Text Styles button not working
The Add Textstyles button is executing an unknown command. "Text" and "Styles" should be 2 words.
Solution:
Map the button to DOTAddWisTextStyles. Change the button and description to say "Add Text Styles".
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\10-CalibriLight.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\20-CalibriRegular.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\30-ArialRegular.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\40-ArialBlack.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\50-ArialNarrow.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Fonts\Palettes\60-ArialNarrowBold.atc
Issue: Remove outdated erosion control blocks
WisDOT BTS Environmental section has requested the following blocks be removed:
- Concrete Split Block Retaining Wall
- Concrete Split Block Wall
- Concrete Surface Drain
- Inlet Protection Details
- Sediment Barrier at Curb Inlet1
- Sediment Barrier at Curb Inlet2
- Sediment Barrier Silt Fence Inlet
- Sediment Filter Sod Inlet
- Sediment Filter Coarse Aggregate for Drop Inlets
- Sediment Filter Coarse Aggregate for Inlets
- Turbidity Barrier Detail
- Silt Screen Detail
Solution:
Removed blocks and block references from cdErosionControl.dwg and palette references to blocks in cdErosionControl.atc.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\cdErosionControl.dwg
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\cdErosionControl.atc
Issue: DOTRefTempStatus variable not working at startup
The DOTRefTempStatus variable is not being checked at startup. This is most noticable if a user had the WisDOT reference templates disabled, and then runs an update. The reference templates are not re-disabled at C3D startup after the update.
Solution:
Update the dll initialization to check the DOTRefTempStatus variable and set the reference template status accordingly.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Differentiate the various types of water valves
There is a need to differentiate the various types of water values on plans. There are currently point codes for "WV", "WVM", and "WVS*", but they all display the same water valve block symbol that says "WV".
Solution:
Add a new block that says "WVM" that is used for WVM point codes. Add a new block that says "WVS" that is used for WVS point codes.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-marker-xsection-symbols.dwt
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkerSymbols\MarkerSymbols.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\MarkerSymbols\XSectionSymbols.dwg
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-point.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: June 2022 WisDOT Sign Plate and Sign Code Manual Transmittal
Block edits and additions need to be added to the sign dwgs and palettes.
Solution:
Edit sign block DWGs and sign palettes to reflect changes from the June 2022 transmittal.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsd.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signse.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsr.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsw.dwg
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\D-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\E-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R1-R3-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R3-R6-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R7-R10-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R11-R59-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\W-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\WZ-Signs.atc
New Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\D5-7064.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\D5-7064_dark.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\R7-6764.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\R7-6764_dark.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\WO8-7864.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\WO8-7864_dark.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-6764.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-6764_dark.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-67A64.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-67A64_dark.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-67B64.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\W21-67B64_dark.PNG
Removed Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E5-51A64.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E5-51A64D.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E5-52A64.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E5-52A64D.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5364.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5364D.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5464.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5464D.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5564.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\E10-5564D.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\WO8-7764.PNG
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\WO8-7764_dark.PNG
Issue: Update Check Sight Distance 24 in (SSD) profile style
According to the WisDOT FDM/SDD Transmittal 424 Update Notification – May 17, 2022, the sight distances standards have been updated to reflect those listed in a more current version of the AASHTO Green Book Edition 2018. Multiple SSD profile styles are no longer needed.
Solution:
Use style SD Available Sight Distance instead of SD Available Sight Distance 24in for 24 in (SSD) profile style.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Update Ewk Material Shape Styles for plotting. Add WisDOT Cross Section QTO Criteria
The shape styles utilized in QTO criteria are not colored for grayscale plotting. Create a QTO criteria for usage on cross section sheets.
Solution:
All shape styles adjusted for plotting. Adjusted scales and hatch style and colors. Added a new QTO Criteria WisDOT Cross Section Sheets.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
Issue: Add Surface Styles for EBS and SubgImp, and Section Style for SubgImp, Marsh Bottom
The templates do not contain surface styles for EBS and subgrade improvement or section styles for subgrade improvement and marsh bottom.
Solution:
Surface Styles EBS Border, EBS Triangles, SubgImp Border and SubgImp Triangles Added. Section Styles SubgImp and Marsh Bottom Added.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-section.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-surface.dwt
Issue: Update SSD_Profile_Dim block
According to the WisDOT FDM/SDD Transmittal 424 Update Notification – May 17, 2022, the sight distances standards have been updated to reflect those listed in a more current version of the AASHTO Green Book Edition 2018.
- Category 3 has been removed
Solution:
Remove Category 3 option from SSD_Profile_Dim block. Minimum/Upper Minimum?
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\NotesTables.dwg
Issue: Structures - Updated Blocks
- Structural approach slab option missing for slab bridges in ABUT_FILL block.
- Keynote leaders for A01, A19, and A15 too small in A1_ABUT block.
- SYMBOL_NUMBER block should have an option for a background mask/wipeout.
- Angle precision too high on PILE_DETAILS block.
- Update DESIGN_CONTACTS block for staff changes.
Solution:
Updated the blocks to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
Issue: Structures - New file dropdown
Structures templates are missing from the New File dropdown list in the Structures profile.
Solution:
Fixed bug in structures profile loading
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\BosData.txt
Issue: Structures - Annotation Palette
The keynote multileader icon was missing, and the button was not working correctly.
Solution:
Fixed the button to work properly and display the icon
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\02-Anno.atc
2022-05-20
Issue: WisDOT Stopping Sight Distance tool
The current Stopping sight distance workflow using mainly OOTB Civil 3D tools is labor intensive.
Solution:
Create a custom tool to more efficiently analyze available stopping sight distance. DOTCheckSightDistance
Objectives: • Add the profile creation directly in the tool, • Analyze both directions, • Simplify the OOTB sight line/layer interface • Simplify the report output
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_CheckSightDistance.png
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv"
Issue: Typical Section from Assembly
User request to utilize an assembly object as the basis for developing a typical section.
Solution:
Create new command DOTCreateTypicalFromAssembly. User selects an assembly object, specifies the desired vertical exaggeration, specifies the desired scale for text height, and picks the location for the typical section. The resulting output consists of lines that trace the displayed links of the assembly and mtext at all slope label location. All resulting entities are placed on the appropriate typical section layers.
New button located on WisDOT Sheets Tab > Sheet Tools > Create Typical From Assembly
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml"
New Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_CreateTypFromAssembly.png
Issue: Simplified Earthwork Detail Report
The current earthwork detail workflow requires unnecessary steps of creating xml files and processing them in a separate application.
Solution:
New Earthwork Detail Report extracts the material section data directly from Civil 3D and populates the Excel worksheet. DOTReportEarthworkDetail
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Add Support for Wetland Property Sets in Survey Template
Need a way to add attributes to Wetland Boundaries. Need a layer for the Wetland Project Area.
Solution:
Add a property set to the survey template that supports wetland types. New layer named E_WTR_Wetland_ProjArea. Updated Layer States to include new layer.
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-property-sets.dwt" "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg" "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg_LayerList.csv"
Issue: New Component: Table Styles and custom MQ table style
Request for searchable Miscellaneous Quantities Sheets. Paste-Link of Excel Tables results in text not searchable.
Solution:
A new workflow was developed that results in searchable table text in the final plan sheets using Excel to C3D Table data links. New Tables.dwg component dwg and table style MQ. New command to load Table Style Components (DOTAddWisTableStyles). Add All Components updated to include these tables. Add new table style to MQ and EW templates.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\03-MQ-SPSHT-wdot.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\09-EW-SPDSHT-wdot.dwt
New Files:
- C:\WisDOT\Stnd\C3D2022\Components\Tables\Tables.dwg
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_Tables.png
Issue: Remove Sight Distance Layers
WisDOT has developed it's own Check Sight Distance tool. This tool creates layers based on the inputs provided. There is no longer a need to preset named layers based on the OOTB Civil 3D tool.
Solution:
Remove preset named Sight Distance Layers from WisDOT customization.
Updated Files:
- "C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\Sight\Palettes\10-SIGHT DISTANCE.atc"
- "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg"
- "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg_LayerList.csv"
Issue: Update P_XS_Bold layer lineweight
The XS Sample Lines Alignment style utilizes the layer P_XS_Bold to define it's display properties. To avoid conflict with P_Misc_Text, modify the lineweight to 0.014", compared 0.10" which is the lineweight of P_Misc_Text, for clarity on XS Matchline sheets.
Solution:
The layer lineweight has been updated. All layers states updated. All templates updated.
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg" "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg_LayerList.csv" "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg" "C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg_LayerList.csv" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-dwg-settings.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt"
Issue: Request: add ticks to contour surface style depressions
A request to add ticks to all WisDOT contour surface styles in the depressions has been approved.
Solution:
All contour surface styles now include ticks in the depressions.
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-surface.dwt"
Issue: Surface from PNT FLT - add error message
If the formatting in the PNT or FLT is not correct, usually extraneous header information in the first few row, the tool gives a windows unhandled exception error. SRV to PNT/FLT tool does not flag when and SRV file is missing the # header on the header lines.
Solution:
Have the Surface from PNT FLT tool catch the error and prompt a message that explains the error and how to fix.
Have the SRV to PNT/FLT tool flag when an SRV file format is incorrect.
Issue: DOTCreateWallSurface: Add options for top of wall elevation and surface name
It can be useful to use wall surfaces to model objects that have a constant top of wall elevation, DOTCreateWallSurface only includes an option to specify the wall height.
Solution:
Add a choice to specify wall height, minimum height, or elevation. Add option to specify the surface name.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Include Excel Add-in
Need a way to deploy the Excel Add-in.
Solution:
Create MSIs for 32-bit and 64-bit Excel. Install as admin.
New Files:
Issue: DOTTransformCSV: Use "USA-Wisconsin" systems
This DOTTransformSRV command uses the retired systems from the WisDOT category.
Solution:
Update the DOTTransformSRV command to use the "USA-Wisconsin" systems
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Slope Control Editor - PVI's out of Order
At times, depending on how the table is developed for a slope control profile, the profile PVI's can be built out of order.
Solution:
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\SlopeControlEditor.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTCivil3DExtensions.dll
Issue: MQ Data Link Generator
The workflow for creating miscellaneous quantity sheets requires the creation of many data links to Excel and AutoCAD Tables. This is a time consuming process.
Solution:
Create a tool that automates the data link generation process. User specifies the Excel document that contains the content to be linked. The tool presents the user with a list of named ranges that are contained in the Excel document. User selects the desired named ranges and the tool creates the data links. An option to create the corresponding AutoCAD tables is also included. Command name is DOTCreateDataLinksAndTables.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\ExcelLogo3DataLink.png
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv"
Issue: DOTSyncProjectFiles: Prevent run on ACC
Sync Project Files is not compatible with ACC project files
Solution:
Add notification to user when attempting to run on ACC projects.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Import SOE error
The import SOE tool is not working. Invalid class string (Exception from HRESULT: 0x800401F3 (CO_E_CLASSSTRING))
Solution:
Tool redeveloped. New command DOTImportSOE
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv"
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
Removed Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\ImportSOE.dll"
Issue: 5 Vert Ex Profile View - Adjust Vertical axis scales
The vertical axis major and minor intervals for 5 vertical ex profile views is too detailed. Since these styles are exaggerated half as much of the 10 vertical scale styles, the intervals need to be doubled.
Solution:
Change the interval to 10' Major and 1' Minor.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: Areas Report Units
When using the "no alignment" option of the Areas Report, the resulting value is always SF, even with the "SY" option selected.
Solution:
Fixed reported value to match the selected units.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Improve access to input CSVs
Users have problems remembering where the input CSVs are located. This concept is to embed the input CSV file location closer to the tool
Solution:
Add content to the dialog box to point users to the standard input CSV files.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Assign Ali Styles, add view default input function
Solution:
Add option to "View" default csv. This option sets the csv to read only and opens it.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Create corridor surfaces, add view default input function
Solution:
Add option to "View" default csv. This option sets the csv to read only and opens it.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Create object folders, add view default input function
Solution:
Add option to "View" default csv. This option sets the csv to read only and opens it.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Parts Catalog: Incorrect part size name
The Storm Sewer Pipe Reinforced Concrete pipe in the WisDOT parts catalog has the incorrect acronym of CRPC in the part size name.
Solution:
Change the parts size name so it has the correct acronym of SSPRC.
Updated Files:
- "C:\WisDOT\Stnd\C3D2022\Program\PipesCatalog\Pipes_USWI\USWI Circular Pipes\WisDOT_AeccCircularRFConcretePipe_StormSewer.xml"
Issue: Section View Style that includes grid
User request for a section view style that includes a grid
Solution:
New section view style (Section Grid) created that contains a grid.
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-section.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt"
Issue: Template Abbreviations
Standard abbreviations set in the drawing settings for Left and Right are not correct.
Solution:
Update standard abbreviations to "LT" and "RT" in all templates.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-dwg-settings.dwt
Issue: ACC Exclude Paths update for sheet layout templates
Desktop Connector 15.6 allows for the exclusion of uploading sheet layout templates, which are used in the Plan Production - Create Sheets wizard in Civil 3D.
Solution:
Update the ExcludePaths-WisDOT.xml to include the WisDOT Sheet templates.
Updated Files:
- C:\ProgramData\Autodesk\C3DFOP\ExcludePaths-WisDOT.xml
Issue: Proposed Culvert Endwall Plan View Display
The proposed culvert endwall structure style utilizes 3D Solid to display in plan view displays. At times, this disappears. Update the style to change the plan view display to "Structure."
Solution:
Update the Proposed Culvert Endwall style > Display > Plan. Turn on Structure. Turn off 3D Solid
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt"
Issue: Pipe Label Styles and Expressions
In some scenarios, the current Pipe Skew label expression does not work.
The Crossing Pipe Label Section-Culvert has an extra space between the stations.
Solution:
Adjust the Pipe Skew Label Expression to utilize the Station Values instead of the offset values to calculate skew.
Adjust the Section-Culvert label style to remove the extra space.
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt" "C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-pipe.dwt"
Issue:
New Erosion Control detail to be added to the erosion control palette. Erosion Control Blocks need updating.
Solution:
Heavy Duty Silt Fence construction detail added to the Erosion Control Palette. All blocks adjusted to scale so all text within blocks sized to standard WisDOT size (0.06 or 0.07). All text made non-annotative and entire block made annotative. Palette Updated to insert blocks at scale=1. This results in blocks inserted into either model or paper space displaying correctly. Removed 5 details due to presence in Standard Detail Drawings. Removed one detail due to duplication. Removed Details:
- Turbidity Barrier Detail
- Silt Screen Detail
- Riprap Heavy Ditch Detail2
- Sediment Barrier Silt Fence Inlet
- Inlet Protection Details
- Concrete Surface Drain
Updated Files:
"C:\WisDOT\Stnd\C3D2022\Components\Blocks\cdErosionControl.dwg" "C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\cdErosionControl.atc"
New Files:
"C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\Images\Silt Fence Heavy Duty.PNG" "C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-1\Palettes\Images\Silt Fence Heavy Duty_Dark.PNG"
Issue: CDP Integrity Report: Check xml units
Need to make sure that LandXML files delivered in the Construction Data Packet have the proper linear units.
Solution:
Add a check to the CDP Integrity Report to verify LandXML linear units.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Create Verification Surface layers do not populate
When using the Create Verification Surface tool does not populate the layer lists in the dialog.
Solution:
Tool fixed so layers are populated.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Layer state inconsistency
The "Set Utilities to Plot in Color" layer state changes the E_DRN_SS_MH, E_DRN_SS_UG, and E_DRN_SS_UG_3D layers, but "Set Utilities to Plot Black" and "Set Utilities to Plot Gray" do not.
"Existing Map Frozen" layer state opens the Layer State Manager.
Solution:
Add the E_DRN_SS_MH, E_DRN_SS_UG, and E_DRN_SS_UG_3D layers to the "Set Utilities to Plot Black" and "Set Utilities to Plot Gray" layer states.
Remove layerstate command from the "Existing Map Frozen" layer state button.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg
- "C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Layers\Palettes\10-LayerStates.atc"
Issue: UDP Classification USWI-ALIGNMENTS is missing from the design template
Station Offsets are not applied to the points when the UDP is missing
Solution:
Add the UDP to the Design Template.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
Issue: Structures - Updated Blocks
- Unneeded dimension in 56SS option for BARRIER block.
- Right side grip for bar series table does not move with the left side grip in BILL_OF_BARS block.
- CULV_CUTOFF block does not match standard details.
- Typos in the DESIGN_DATA block.
- Origin grip is sometimes not centered in the HP_SHAPES block.
- LANE_ARROWS block is not scaled correctly to work in LAYOUT & GEO template files.
- NOTE_CALL block missing descriptions for notes.
- RIPRAP_TOE block text style is inconsistent
- Steel shape blocks should be placed on layer 0 to allow for more control in drafting styles.
Solution:
Updated the blocks to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\structures.dwg
Issue: Structures – No plot layer
The B_ANNO_NOPLOT layer viewport overrides do not get copied between viewports, which can be confusing
Solution:
Updated B_ANNO_NOPLOT layer to remove viewport overrides.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\struct-inch-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\struct-decimal-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Sheets\08-STRUCT.dwt
Issue: Structures – Riprap linetype scale
The Eripr linetype used in the B_GRND_RIPRAP layer is half as big as it needs to be in structures plans.
Solution:
Added a Riprap button in the Gen Plans palette from the Structures tool palette. This button starts the multiline command, sets the active layer to B_GRND_RIPRAP, and sets the linetype scale to 2.0.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\03-General.atc
Issue: Structures – Request for ability to quickly remove annotative scales
Leaving the ANNOAUTOSCALES setting on will add multiple annotative scales to annotative objects. These additional scales can be confusing and are typically unnecessary in structures plans.
Solution:
Added a tool to the Structures tool palette to “Fix Annotation Scales”. This tool removes all annotative scales except the currently active scale from selected annotative elements.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\ 01-Templates.atc
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.acad.dll
Issue: Structures – Request for ability to purge non-structures styles
Purge all will remove structures layers and styles that may be needed as well as unneeded elements. As a workaround, structures layers and styles must be unchecked from the purge dialog.
Solution:
Added a tool to the Structures tool palette to “Purge Non-Structures Styles”. This tool performs a Purge All while retaining all structures layers and styles.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\08\Palettes\ 01-Templates.atc
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.acad.dll
Issue: Structures – DGN Conversion Updates
- Conversions to Layout templates are 12 times too big
- Multileaders do not convert properly
- Some dimension text does not convert properly
Solution:
Updated to DGN conversion tool to fix these issues.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.acad.dll
Issue: Structures Profile
There are several settings used by structures plans drafters that differ from the standard WisDOT profile settings.
- ANNOAUTOSCALE: off
- ATTREQ: Use default values for attributes
- ATTDIA: Use command prompts
- ATTIPE: Use full formatting options
- DGNIMPORTMODE: Import into active drawing
- Use structures drawing templates as the default for new files
Solution:
There is now a separate Structures Profile that can be accessed by opening the Structures tool Palette from the WisDOT Sheets ribbon. A new desktop shortcut will be created that launches the structures palette.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\wisdot.bos.drafting.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDot.Bos.Acad.Settings.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\BosData.txt
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\2022wisdotBOS.arg
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Civil 3D 2022 WisDOT-BOS.lnk
2022-02-15
Issue: BG EAT L Curve Block Incorrect Dimensions
The parametric block for the BG EAT L Left Curve is incorrect. When using a smaller radius, the length of the guardrail is shorter than 53.125' as shown in the SDD.
Solution:
Updated the block to be correct.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\Parametric\param-bg-eat.dwg
Issue: Construction Data Packet Integrity Report
Construction Data Packet quality has been inconsistent.
Solution:
New tool DOTReportCDPIntegrity to check:
- Does DWG contain Civil 3D object data?
- Does DWG contain XReferences?
- Does surface XML contain breakline data?
- Does surface XML contain boundary data?
- Does surface XML contain multiple surfaces?
- Is metadata file present?
- Is DT1773 file present?
- Is contractor feedback form present?
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Issue: Intersection Sight Distance
Need a way to quickly check intersection sight distance
Solution:
New command DOTCheckISD can be run to check intersection sight distance. The tool provides checks sight distance utilizing input options for decision point location, eye height, required sight distance, target vehicle path, and target surface.
Add the attached (ISD-Layers.png) supporting layers to Layers.dwg. Include "P_SIGHT_Text" in the "Sight Distance" layer filter.
Add button to Sight distance palette to import ISD sight distance layers. Command is DOTADDWIS-SIGHT-ISD-LAYERS.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
- C:\WisDOT\Stnd\C3D2022\Components\Layers\Layers.dwg
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\Sight\Palettes\SIGHT DISTANCE.atc
- C:\WisDOT\Stnd\C3D2022\Components\Layers\LayerFilters\wisdot-layer-filter.lft
- C:\WisDOT\Stnd\C3D2022\Components\Layers\LayerFilters\wisdot-layer-filter-with-xrefs.lft
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\plat-start.dwt
- C:\WisDOT\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
New Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_CheckIntersectionSightDistance.png
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\C3D_VisibilityCheck.png (for new drop down menu)
Issue: Create Verification Surface
The process of creating a verification surface for the breakline extraction workflow is time consuming.
Solution:
New tool "Create Verification Surface". The tool is run from the breakline raw data file. It copies the pertinent breakline and boundary data into a new file and creates a new surface from that data. The design surface is data referenced into the drawing and a verification surface is created (volume surface) to compare the design surface and breakline surface. Command is DOTCREATEVERIFICATIONSURFACE. It can be accessed from the WisDOT Design tab - Output panel - Contractor Data menu
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\en-US\HelpResources.csv
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\xaml\wisdot-ui.xaml
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Res\Icons\CreateVerificationSurface.png
Issue: Revised WisDOT Standard Sign Plates transmittal issued December 2021
Edit Sign Blocks per Revised WisDOT Standard Sign Plates transmittal issued December 2021
Solution:
Created/Edited Sign Blocks per December 2021 transmittal and added blocks to Signs palettes.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signse.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsi.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsm.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsr.dwg
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\signsw.dwg
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\E-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\M-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\O-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R1-R3-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R7-R10-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\R11-R59-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\W-Signs.atc
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\WZ-Signs.atc
New Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Standards\Wis-Signs\Palettes\Images\*.png
Issue: Request for Trailer Mounted Signal Block per SDD 09G02 - 05c
Request for Trailer Mounted Traffic Signal Block per detail SDD 09G02 - 05c
Solution:
Created TrailerTrafficSignal dynamic block and added to Traffic Control palette.
Updated Files:
- C:\WisDOT\Stnd\C3D2022\Components\Blocks\TrafficControl.dwg
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-4\Palettes\Traffic Control.atc
New Files:
- C:\WisDOT\Stnd\C3D2022\Appdata\ToolPalette\Sheets\02-4\Palettes\Images*.*
Issue: Updated project directory template
- lower-casing and shortening folders to ensure maximum flexibility in ACC with the current fixed local location and the 256 character limit for windows folder/filenames.
- improvements/corrections to the folder structure based on experience with the existing structure
Solution:
File structure revised for Civil 3D 2022.
Updated Files:
- C:\Users\Public\Documents\Autodesk\Civil 3D Project Templates\WisDOTProjectTemplate
Issue: Import PI ALI File button
The "beta" tag can be removed from this tool's button.
Solution:
Remove "beta" from the tool button. Move the button into the location where "ALI Translator" sits. Remove "Ali Translator" button.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Menu\WiRibbon24-1.cuix"
Issue: Corrected input CSVs for CrdrTrgtAssgn-BeamGuard.csv and CrdrTrgtAssgn-FullSection.csv
The above input CSV files had missing and incorrect variables set.
Solution:
The above input CSV files had corrections and updates made for Offset to measure recoverable distance from and Shoulder foreslope.
Updated Files:
- C:\wisdot\Stnd\C3D2020\Components\Assemblies\CrdrTrgtAssgn-BeamGuard.csv
- C:\wisdot\Stnd\C3D2020\Components\Assemblies\CrdrTrgtAssgn-FullSection.csv
Issue: Add ShldPave1 to XS Sheets with Shapes
The XS Sheets with Shapes code set style is missing the shoulder shape code ShldPave1
Solution:
Add ShldPave1 shape code to XS Sheets with Shapes. Assign Shape Style of CRDR Proposed.
Updated Files:
- C:\Wisdot\Stnd\C3D2022\Templates\Begin-dwg\design-start.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Begin-dwg\survey-start.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\group-design.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\ref-general.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\ref-qto.dwt
- C:\Wisdot\Stnd\C3D2022\Templates\Template-ref\ref-survey.dwt
Issue: New Ali Label Styles for XM and JD Sheets
New alignment label styles were created for developing cross section matchline and joint detail sheets.
Solution:
New Styles include
- Spot Elevation - Text Above Point - Leader
- Spot Elevation - Text Below Point - Leader
- Station - Truncated
Updated Files:
C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-survey.dwt C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-design.dwt C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\group-plat.dwt C:\WisDOT\Stnd\C3D2022\Templates\Template-ref\ref-align-prof.dwt
Issue: Add no alignment option for Lengths Report and Areas Report
Need a way to get areas and lengths quickly without an alignment and without creating a report file.
Solution:
The alignment selection is now optional for the Lengths Report and Areas Report. If an alignment is not selected, an alert dialog will appear with the total length/area of the selected objects. Precision and units settings still apply.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: Station Increment Labels - Station Equations
The tool "Station Increment Labels" does not account for station equations.
Solution:
Update the tool to account for station equations.
Updated Files:
- "C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll"
Issue: System Variable EnableDSTLock set to 1
With Autodesk Construction Cloud, DST files are not automatically locked. Autodesk created a registry variable to automatically lock DST files.
Solution:
Set this variable to 1 for internal installs. EnableDSTLock=1 on startup.
Updated Files:
- C:\ProgramData\Autodesk\ApplicationPlugins\Wi24.1.bundle\Content\WisDOTExt2022.dll
Civil 3D 2022 Interface and tool update
-
Status bar on/off setting is persistent across drawings
-
WisDOT ribbon tabs are refreshed at each startup
-
Update WisDOT Civil 3D.exe resets the WisDOT profile after each update.
-
DOTIMPORTDESCKEYS (formerly ImportWIDescKeys)
- Imports point styles without a separate marker block import operation
- Pulls point styles directly from the ref-point.dwt instead of ref-point.dwg
- Updates existing description key set instead of making a copy.
-
WisDOT reference templates system variable: NEW.
- introduced a new system variable DOTRefTempStatus. Value >=1: templates on. Value <1 templates off.
- Initial setting is 1. The value is persistent through updates, so if a user turns them off, they will stay off after an update.
-
DOTROTATEVIEW (formerly DOTViewRotate`)
- Added rubberband
-
DOTVIEWEXPORT & DOTVIEWDELETE are retired.
-
Replaced with DOTIMPORTVIEWS
- Imports views directly from the source dwg.
- Presents user with list of views to select from in the source dwg to import.
-
-
DOTLABELASSEMBLIES
- Set text to not annotative
- Detects if assemblies are already labeled and skips them if they are
-
DOTLabelSectionSheets (formerly XSAT)
- Option to select individual section sheets or all section sheets
- No longer need to pick points to determine sheet location/spacing
- Sheet labels are now fields that read the sheet names.
-
DOTLoadXRefsOnLayers (formerly LXRSL)
- Added support for loading multiple XReferences
-
Add components performance improvements
- Set-<LayerName>: If layer does not exist, imports only that layer instead of all layers followed by a purge
- DOTAddWisDOTTextStyles (formerly DOTAddWisTStyles): Imports styles only without the need to purge
- DOTADDWISDIMSTYLES: Imports styles only without the need to purge
- DOTADDWISLINETYPES: Imports directly from the Linetypes.dwg
- DOTADDWISMULTILEADERS: Imports styles only without the need to purge
- DOTADDWISLAYERS: If layers exist, they are not overwritten.
- DOTADDSECTBLOCKS: Imports blocks only without the need to purge
- DOTADDWISSYMBLOCKS: Imports blocks only without the need to purge
- DOTAddWisPartsLists (formerly DOTAddWisPipeNetwork: Connects drawing to the corresponding pay item files.
-
DOTRotateAnnoToViewport (formerly AMLT)
- Add option to select by object types (MText, Text, Multileader, Block Reference), using dialog listbox
- Type selection option uses the rectangular bounding box of the viewport as a crossing selection.
-
DOTStaIncLabels (formerly SOELA)
- Selection stations by pick points
- If target object is an alignment, that alignment becomes the parent for the label. This forces the label rotation to match the target alignment.
-
LS_LayerStateName (formerly LAS_LayerStateName )
- Imports directly from the layer state source dwg.
- If layer state exists, it is updated.
- Applies layer state to xref layers
-
DOTReplaceBlocks (formerly DOTBlkReplace)
- Allows pick-first option for more flexible block reference selction
- Presents user with a list of block in the drawing that can be used as the replacement
-
WSAUTOSAVE Is set to 1 at startup.
This was done to keep user command line orientation settings in place between sessions.
-
DOTCreateWallSurface: NEW.
Surface creation tool used to make (near) vertical face surfaces from a single Feature Line, Survey Figure, or 3D Polyline. Useful fill for creating obstructions for sight distance workflows.
-
WisDOT custom coordinate systems have been retired
All coordinate systems formerly found in the "WisDOT" category have been moved to the "Obsolete Coordinate Systems" category. These coordinate systems are no longer needed. Users should refer to the coordinate systems found in the "USA, Wisconsin" category moving forward. Issues identified with the "USA, Wisconsin" coordinate systems in previous versions have been resolved. Users do not need to reassign coordinate systems if they used "WisDOT" coordinate systems for existing drawings.
-
Object right click command menu shortcut added for the following commands:
- Move Pipe End
- Pipe Separation at Structures
- Label Assemblies
- Profile View Elevation Range