The WisDOT Civil 3D standards require custom AutoCAD multileader styles. WisDOT custom multileader styles reside in a multileader style component file that is included in the WisDOT Civil 3D resource files.
Warning: Altering WisDOT component files and directories may result in lost functionality. Contact CAE Support for more information.
When starting a project from a WisDOT template, the WisDOT templates are purged of all WisDOT standards components except those necessary for WisDOT Civil 3D Styles. To add all WisDOT standards components groups at once (symbol blocks, dimension styles, layers, linetypes, multileaders, and textstyles) use Add All Components. Each WisDOT standards component group can also be added individually to a drawing.
User component files can be created and stored in C:\WisDOT\Stnd\users\Myc3d20xx\
New custom multileader style requests can be directed to the WisDOT Civil 3D Futures Trello board for review and consideration.
Resource files
Multileader style component files
The WisDOT multileader style component file consists of an AutoCAD drawing. The file is located in: C:\WisDOT\Stnd\C3D20xx\Components\Dimensions
-
Mleaderstyles.dwg is a drawing displaying all the WisDOT custom multileader styles in model space.
Multileader style lists
Specific WisDOT custom multileader style use cases can be found in the Plan production section of the C3DKB.
General multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
050 | CalibriLight |
0.05 |
Closed filled |
0.06 | <user defined mtext> |
060 | CalibriLight | 0.06 |
Closed filled |
0.08 | <user defined mtext> |
060-CIRCLE TAG | CalibriLight |
0.06 |
Closed filled | 0.08 | <block attribute text> |
060-HEX TAG | CalibriLight | 0.06 | Closed filled | 0.08 | <block attribute text> |
060-LIGHTING LOOP | CalibriLight | 0.06 | LightingLoop | 0.06 | No text |
060-NO ARROWHEAD | CalibriLight | 0.06 | None | n/a | <user defined mtext> |
060-OVAL TAG | CalibriLight | 0.06 | Closed filled | 0.08 | <block attribute text> |
060-PC PT | CalibriLight | 0.06 | Dot blank | 0.06 | <user defined mtext> |
060-SQUARE TAG | CalibriLight | 0.06 | Closed filled | 0.08 | <block attribute text> |
070 | CalibriLight | 0.07 |
Closed filled |
0.10 | <user defined mtext> |
070-CIRCLE TAG | CalibriLight | 0.07 | Closed filled | 0.10 | <block attribute text> |
070-HEX TAG | CalibriLight | 0.07 | Closed filled | 0.10 | <block attribute text> |
070-LIGHTING LOOP | CalibriLight | 0.07 | LightingLoop | 0.07 | No text |
070-NO ARROWHEAD | CalibriLight | 0.07 | None | n/a | <user defined mtext> |
070-OVAL TAG | CalibriLight | 0.07 | Closed filled | 0.10 | <block attribute text> |
070-PC PT | CalibriLight | 0.07 | Dot blank | 0.07 | <user defined mtext> |
070-SQUARE TAG | CalibriLight | 0.07 | Closed filled | 0.10 | <block attribute text> |
0875 | CalibriLight | 0.0875 | Closed filled | 0.10 | <user defined mtext> |
100 | CalibriLight | 0.100 | Closed filled | 0.10 | <user defined mtext> |
Title Sheet multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
BEGIN PROJECT-STA | ArialRegular | 0.10 | Closed filled | 0.40 |
BEGIN PROJECT STA XXX+XX |
END PROJECT-STA | ArialRegular | 0.10 | Closed filled | 0.40 |
END PROJECT STA XXX+XX |
STRUCTURE B STA-STA | CalibriRegular | 0.07 | Closed filled | 0.10 |
END TEMPORARY PAVEMENT MARKING STA XXX+XX |
NET EXCEPTION TO CL LENGTH STA-STA | CalibriRegular | 0.07 | Closed filled | 0.10 |
NET EXCEPTION TO CL LENGTH STA XXX+XX - STA XXX+XX |
EQUATION STA-BK-STA-AHD | CalibriRegular | 0.07 | Closed filled | 0.10 |
EQUATION STA XXX+XX BK= STA XXX+XX AHD |
X-Y | CalibriLight | 0.07 | Closed filled | 0.10 |
STA XXX+XX GRAVEL PE |
T-#-N | CalibriLight |
0.06 |
None | n/a | T-##-N |
R-#-E | CalibriLight | 0.06 | None | n/a | R-##-E |
Typical Section multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
PNT REF TO ON PROFILE | CalibriLight | 0.07 | Closed filled | 0.10 |
POINT REFERRED TO ON PROFILE |
PNT REF TO ON XS | CalibriLight | 0.07 | Closed filled | 0.10 |
POINT REFERRED TO ON CROSS SECTION |
TOPSOIL-SEED-MULCH | CalibriLight | 0.07 | Closed filled | 0.10 |
TOPSOIL, SEED, FERTILIZER & MULCH |
SALVAGED TOPSOIL | CalibriLight | 0.07 | Closed filled | 0.10 |
SALVAGED TOPSOIL, SEED, FERTILIZER & MULCH |
SEED-FERTILIZER | CalibriLight | 0.07 | Closed filled | 0.10 | SEED & FERTILIZE |
CONCRETE CURB-GUTTER | CalibriLight | 0.07 | Closed filled | 0.10 |
CONCRETE CURB & GUTTER 30-INCH, TYPE A |
6-INCH CONC ISLAND | CalibriLight | 0.07 | Closed filled | 0.10 |
6-INCH CONCRETE SAFETY ISLAND |
CONCRETE SIDEWALK | CalibriLight | 0.07 | Closed filled | 0.10 |
5" CONCRETE SIDEWALK |
SEE CONST DETAIL | CalibriLight | 0.07 | Closed filled | 0.10 | SEE CONSTRUCTION DETAIL |
TYP EXIST SECT TITLE | ArialRegular | 0.10 | Closed filled | 0.10 |
TYPICAL EXISTING SECTION STA XXX+XX TO XXX+XX |
TYP FINISHED SECT TITLE | ArialRegular | 0.10 | Closed filled | 0.10 |
TYPICAL FINISHED SECTION STA XXX+XX TO XXX+XX |
Plan sheet multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
ROW | CalibriLight | 0.07 | Closed filled | 0.10 | R/W |
EXISTING ROW | CalibriLight | 0.07 | Closed filled | 0.10 | EXISTING R/W |
TLE | CalibriLight | 0.07 | Closed filled | 0.10 | TLE |
BEGIN CONST-STA MATCH | CalibriLight | 0.07 | Closed filled | 0.10 |
BEGIN CONSTRUCTION STA XXX+XX MATCH EXISTING SAW CUT REQ'D |
END CONST-STA MATCH | CalibriLight | 0.07 | Closed filled | 0.10 |
END CONSTRUCTION STA XXX+XX MATCH EXISTING SAW CUT REQ'D |
SI | CalibriLight | 0.07 | Closed filled | 0.10 | SI |
REMOVE EXIST PIPE-STA | CalibriLight | 0.07 | Closed filled | 0.10 |
STA XXX+XX REMOVE EXISTING PIPE |
GRAVEL PE-STA | CalibriLight | 0.07 | Closed filled | 0.10 |
STA XXX+XX GRAVEL PE |
WETLAND | CalibriLight | 0.07 | Integral | 0.10 | WETLANDS |
Profile sheet multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
PROPOSED PROFILE | CalibriLight |
0.07 |
Closed filled |
0.10 | PROPOSED PROFILE |
ORIGINAL GROUND | CalibriLight | 0.07 | Closed filled | 0.10 | ORIGINAL GROUND |
Traffic control multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
BEGIN TEMP PAVE MRKG | CalibriLight | 0.07 | Closed filled | 0.10 |
BEGIN TEMPORARY PAVEMENT MARKING STA XXX+XX |
END TEMP PAVE MRKG | CalibriLight | 0.07 | Closed filled | END |
BEGIN TEMPORARY PAVEMENT MARKING STA XXX+XX |
TEMP PAVE MRKG 4IN WHITE | CalibriLight | 0.07 | Closed filled | 0.10 |
TEMPORARY PAVEMENT MARKING REFLECTIVE PAINT 4-INCH WHITE EDGELINE STA XXX+XX |
TEMP PAVE MRKG 4IN YELLOW | CalibriLight | 0.07 | Closed filled | 0.10 |
TEMPORARY PAVEMENT MARKING REFLECTIVE PAINT 4-INCH YELLOW EDGELINE STA XXX+XX |
TEMP PAVE MRKG CL DBL | CalibriLight | 0.07 | Closed filled | 0.10 |
TEMPORARY PAVEMENT MARKING REFLECTIVE PAINT 4-INCH DOUBLE YELLOW STA XXX+XX |
REMOVE DBL YELLOW CL | CalibriLight | 0.07 | Closed filled | 0.10 |
REMOVE DOUBLE YELLOW C/L STA XXX+XX |
REMOVE 4IN EDGELINE | CalibriLight | 0.07 | Closed filled | 0.10 |
REMOVE 4-INCH EDGELINE STA XXX+XX |
FLEXIBLE TUBULAR MARKERS | CalibriLight | 0.07 | Closed filled | 0.10 |
FLEXIBLE TUBULAR MARKERS STA XXX+XX |
Sight distance multileaders and settings
Multileader style | Textstyle | Text height | Arrowhead | Size | Default text content |
---|---|---|---|---|---|
DSD DIST BACK | CalibriLight | 0.07 | Closed filled | 0.10 | DISTANCE BACK FROM END NB CATEGORY X = SSD |
DSD SIGHT DIST REQ | CalibriLight | 0.07 | Closed filled | 0.10 |
CATEGORY X UPPER MINIMUM SIGHT DISTANCE REQUIRED DSD-C FOR XX-MPH (XX-IN OBJECT) |
SIGHT CATEGORY BEGIN | CalibriLight | 0.07 | Closed filled | 0.10 |
BEGIN NB CATEGORY X |
SIGHT CATEGORY END | CalibriLight | 0.07 | Closed filled | 0.10 |
END NB CATEGORY X |
SIGHT DIST AVAIL | CalibriLight | 0.07 | Closed filled | 0.10 |
NB SIGHT DISTANCE AVAILABLE TO XX-IN OBJECT |
SIGHT DIST REQD MIN | CalibriLight | 0.07 | Closed filled | 0.10 |
CATEGORY X MINIMUM SIGHT DISTANCE REQUIRED SSD FOR XX-MPH (XX-IN OBJECT) |
SIGHT DIST REQD UP MIN | CalibriLight | 0.07 | Closed filled | 0.10 |
CATEGORY X UPPER MINIMUM SIGHT DISTANCE REQUIRED SSD FOR XX-MPH (XX-IN OBJECT) |
SIGHT LIMITS | CalibriLight | 0.07 | Closed filled | 0.10 | ESTIMATED HORIZONTAL LIMITS FOR REQUIRED SIGHT DISTANCE |
Using multileader styles
The available multileader styles in an active DWG can be found at:
- Ribbon > Annotate tab > Leaders panel > Multileader Style dropdown
-
Ribbon > WisDOT Sheets tab > WisDOT Annotation panel > Multileader Style dropdown
To add all the WisDOT custom multileader styles to a drawing as a group, use the Multileaders Add component group command.
WisDOT custom multileader styles can be added to a drawing individually from the drawing tools in the Multileader palette group.
The current multileader style can be set by using the WisDOT Multileader style picker and tool.